グループ: Noris Group
カタログの抜粋

Rotary position sensor with ohmic signal output or voltage output Change in resistance on the voltage divider, hall-effect Measuring range Type R1: 50° ... 360° in 10° steps (linear acquisition angle) Type U2: 50° ... 360° in 10° steps (linear acquisition angle) Rotation angle 360° without mechanical limitation Output signal Type R1: 2 signal outputs: 0 ... 2 kΩ Type U2: 2 signal outputs: 2 ... 10 VDC, crossed characteristic curves Operating temperature Protection class Electrical connection Design Q1: Push-in terminals for max. 2.5 mm², with M20 screw connection as per DIN EN 50262 for cable diameter 9 to 13 mm Design Q2: 4x 2x 0.5 mm² fixed connection cables, 3 m in length, with M16 screw connection as per DIN EN 50262 Rotary position sensor DWA-Q Measuring principle Special features Scope of application The type DWA-Q rotary position sensors are robust, maintenance-free sensors that are particularly used in the Shipbuilding industry and machinery and plant engineering industry to convert the mechanical rotation angle of a shaft into an electrical signal (e.g. for measuring the rudder angle or adjusting the pitch). • Reference position mark • Maintenance-free operation • No reference run necessary • Potential-separated channels Measuring principle The instrument shaft is connected to a double sensor. Depending on requirements, the angle position that can be acquired electronically (50° ... 360° in 10° steps (linear acquisition angle)) must be selected and adjusted within a mechanical revolution. The version with ohmic resistor connection provides a passive electrical signal; the version with analogue current output provides an active electrical signal. Datasheet DB-DWA-Q-EN | V01.01 | 15/12/2017 | Valid from product revision B | www.noris-group.com | sales@
カタログの1ページ目を開く
| Dimensioned drawing, connection and wiring diagrams NORIS Automation GmbH Dimensioned drawing, connection and wiring diagrams DWA-Q1 (design Q1) dimensions and wiring diagram for push-in terminals up to max. 2.5 mm2 C A: Length 115 mm B: Length 40 mm C: Length 25 mm D: Ø 40h7 mm E: Ø 12h7 mm F: 62x62 mm G: Length 30 mm Wiring diagram for ohmic resistor connection Wiring diagram for analogue voltage output A: Length 62 mm B: Length 92 mm C: Length 62 mm D: Ø 70 mm E: 4 x M6x7 mm F: 90° Information on the connection diagram: Tap-off point on the voltage divider in arrow direction when the...
カタログの2ページ目を開く
NORIS Automation GmbH Dimensioned drawing, connection and wiring diagrams | Type DWA-Q...-R1 in version with ohmic signal output, passive electrical signal A centre-tapped potentiometer serves as the measuring element. The change in resistance corresponds linearly to the angle position within the electrical acquisition range. A power supply is not necessary for this. The ohmic signal for the respective acquisition range of the DWA can be converted into a standard 2–10 V DC signal by means of a signal amplifier (e.g. NORIS SA502-3G) (see following figures). Diagram of the DWA-Q…-R1 range R...
カタログの3ページ目を開く
NORIS Automation GmbH Technical data Common technical data Measuring principle Change in resistance on the voltage divider, hall-effect Rotation angle 360° without mechanical limitation Vibration resistance 4 g DIN IEC 60068-6 increased stress, characteristic curve 2 (2 ... 100 Hz) Shock resistance (impact) Climatic test Operating temperature Storage temperature -40 ... 70°C (max. peak values within 30 days/year at relative humidity of 5–95%) Insulation voltage Protection class Electrical connection Design Q1: Push-in terminals for max. 2.5 mm², with M20 screw connection as per DIN EN 50262...
カタログの4ページ目を開く
NORIS Automation GmbH Type code Type code structure DWA 90 Rotation angle Design Signal output DWA... type code Rotation angle Customised rotation angle: 10° … 360° in 10° steps (special type) Output signal 62 x 62 x 115 mm design with terminals and Ø 40 mm connection pin 62 x 62 x 66 mm design with cable and Ø 30 mm connection pin -R1 -U2 Dual potentiometer 2 kΩ 2 x voltage output 2 … 10 VDC, crossed characteristic curves Example: DWA70-Q1-U2 (Preferred type) Preferred types Features marked with a symbol at the end of the line are preferred features. If you select a preferred feature for...
カタログの5ページ目を開くNORIS Group GmbHのすべてのカタログとパンフレット
-
Unique Yacht Automation
16 ページ
-
Datasheet TAV131
3 ページ
-
Datenblatt VFS5
2 ページ
-
Datasheet PAx9
6 ページ
-
Datasheet RG5
2 ページ
-
Datasheet VFW5
2 ページ
-
Datasheet RP5, RPT5
2 ページ
-
Datasheet NIR3 NIQ3
20 ページ
-
Datasheet VD61
6 ページ
-
Datasheet FA13
14 ページ
-
Datasheet NIQ31
16 ページ
-
NORIS Marine Overview
13 ページ
-
Datasheet FA54
11 ページ
-
NORIS Brochure
15 ページ
-
Datasheet TP31 TH31
5 ページ
-
Datasheet EOT
6 ページ
-
Datasheet DWA
4 ページ
-
Datasheet TP23
4 ページ
-
Datasheet VF5
2 ページ
-
Flyer NORISYS 4 CPU
2 ページ
-
Datasheet RFW5
2 ページ
-
Datasheet RTK5
2 ページ
-
Datasheet RFJ5
2 ページ
-
Datasheet VTK5
2 ページ
-
Datasheet RF5
2 ページ
-
Datasheet RI5
2 ページ
-
Datasheet RFG5
2 ページ
-
Datasheet VPT5
2 ページ
-
Datasheet RH5
2 ページ
-
Datasheet VFS5
2 ページ
-
Datasheet RH41M
2 ページ
-
Datasheet RW5
2 ページ
-
Datasheet VMP70
3 ページ
-
Datasheet VP5
2 ページ
-
Datasheet NADS3
2 ページ
-
Datasheet NAD2
2 ページ
-
Datasheet NAD1
2 ページ
-
Flyer NORISYS 4
2 ページ
カタログアーカイブ
-
Datasheet GE12
2 ページ
-
Datasheet GE14
2 ページ