

カタログの抜粋

Self-contained, single color, electronic plural component paint proportioner. For professional use only. Important Safety Instructions Read all warnings and instructions in this manual. Save these instructions. See page 3 for model information, including maximum working pressure and approvals.
カタログの1ページ目を開く
Manual Conventions Contents Manual Conventions . . . . . . . . . . . . . . . . . . . . . . . . 2 ProMix Easy Models . . . . . . . . . . . . . . . . . . . . . . . . 3 Related Manuals . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Usage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 User Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Installation . . . . . . . . . . . . . . . . . . . . . . ....
カタログの2ページ目を開く
ProMix Easy Models ProMix Easy Models WARNING Do not install equipment approved only for non-hazardous location in a hazardous area. Substitution of components may impair intrinsic safety and cause personal injury. Read page 5. Approved for Hazardous Location Class I, Div 1, Group D (North America); Class I, Zones 1 and 2 (Europe) ProMix Easy Part No. Maximum Working Pressure psi (MPa, bar) Cart mount, UltraMix™ cst* Pumps, hose and gun Wall mount, UltraMix cst* Pump/G3000 Meter Wall mount, UltraMix sst** Pump/G3000 Meter Wall mount, UltraMix cst* Pumps Wall mount, UltraMix sst** Pumps Wall...
カタログの3ページ目を開く
Related Manuals Related Manuals Component Manuals in English This manual available in the following languages: ProMix Easy Operation ProMix Easy Repair-Parts Dispense Valve UltraMix and HydraMix Displacement Pumps UltraMix Pumps HydraMix Pumps Circulation Kits Stand and Caster Kits Data Download Kits Turbine Alternator Repair Kit
カタログの4ページ目を開く
Warnings The following general warnings are related to the safe setup, use grounding, maintenance, and repair of this equipment. Additional more specific warnings may be found throughout the text of this manual where applicable. Warning FIRE AND EXPLOSION HAZARD Flammable fumes, such as solvent and paint fumes, in work area can ignite or explode. To help prevent fire and explosion: • • Use equipment only in well ventilated area. Eliminate all ignition sources; such as pilot lights, cigarettes, portable electric lamps, and plastic drop cloths (potential static arc). Keep work area free of...
カタログの5ページ目を開く
Overview Usage The ProMix Easy can mix most two-component paints. It is not for use with “quick-setting” paints (those with a pot life of less than 5 minutes) without modification. Contact your distributor for information. The ProMix Easy is operated with the User Interface, Air Controls and Fluid Controls, described below and on page 10. Refer to FIG. 1 and FIG. 3. User Interface The User Interface has 6 main interfaces. 4. Key switch to change ratio, pot life time, pot life volume, or calibration data. 5. Display (five digits) to view: • Software revision level at startup • Ratio • Pot...
カタログの7ページ目を開く
Installation The Typical Installation shown in FIG. 3 is not an actual system design. Contact your Graco distributor for assistance in designing your system. Be sure all accessories are adequately sized and pressure-rated to meet system requirements. Reference numbers and letters in the text refer to numbers and letters in the figures. Power Connection (non-IS units only) ProMix Easy non-IS units operate with 93-250 Vac, 50/60 Hz input power, with a maximum 1.2 amp current draw. The power supply circuit must be protected with a 15 amp maximum circuit breaker. A switch or circuit breaker...
カタログの8ページ目を開く
FIG. 3. Typical Installation (Wall Mount, Air-Assisted Unit Shown) Key for FIG. 3 A B C D E F G H J K L M N P R S ProMix Easy Plural Component Proportioner User Interface (see page 7) Mix Manifold Bleed-Type Main Air Shutoff Valve Air Supply Pressure Gauge Pump Air Regulator (pump-based units only) Pump Air Pressure Gauge (pump-based units only) Component A Pump Component A Fluid Supply Line Component A Fluid Supply (5 gal. pail shown) Component B Pump Component B Fluid Supply Line Component B Fluid Supply (pressure pot shown) Gun Air Pressure Regulator (accessory) Gun Air Supply Line Gun...
カタログの9ページ目を開く
Sampling valves (HA, HB), to batch dispense or test pumps/meters. Solvent purge valves (JA, JB) allow solvent to enter the fluid manifold. Bleed-type main air shutoff valve (D), to shutoff all air to ProMix Easy (including controller power). Supply air pressure gauge (E), to monitor air pressure to ProMix Easy. A minimum air pressure supply of 70 psi (483 kPa, 4.8 bar) must be maintained for the ProMix Easy to operate properly. Pump air pressure regulator (F) with gauge (G), to adjust and monitor pump air pressure (not present on meter-based systems). Gun air regulator (P) and gauge,...
カタログの10ページ目を開く
Solenoid A opens dispense valve A. The correct dose of component A flows into the integrator (Z). Solenoid A closes dispense valve A. See FIG. 4. Solenoid B opens dispense valve B. The correct dose of component B flows into the integrator (Z) and is aligned proportionately with component A. Solenoid B closes dispense valve B. The components are pre-mixed in the integrator, then uniformly blended in the static mixer tube (ST). See FIG. 5. FIG. 4. Component A Dispense ST FIG. 5. Component B Dispense
カタログの11ページ目を開く
Setup 4. Pump-based models only: Fill pumps A and B pack- ing nuts with throat seal liquid (TSL). Do not install equipment approved only for non-hazardous location in a hazardous area. Substitution of components may impair intrinsic safety and cause personal injury. Read warnings, page 5. Ground equipment as instructed below. 1. Connect ProMix Easy ground wire (W) to a true earth ground. 5. Connect air supply line (V) to air inlet. Air supply requirement: 110 psi (0.8 MPa, 8 bar) maximum, 70 psi (483 kPa, 4.8 bar) minimum. Flow volume required: 20 scfm minimum; 125 scfm maximum....
カタログの12ページ目を開く
6. Pump-based models only: Set air regulator to 0. 9. Flush and prime system. See pages 16 and 20. Run Pump Test, page 22 to check ratio accuracy. 7. Open main air shutoff valve. When starting up, display will show “88888”, then software revision, then current ratio (if set to 8. Setup ratio. a. Turn function knob to b. Current ratio displays. c. To change ratio, turn key to + or – until desired ratio is displayed, then turn key back to neutral.
カタログの13ページ目を開くGracoのすべてのカタログとパンフレット
-
FRP Chopper
18 ページ
-
G-Force II
4 ページ
-
SHIP & RIG BUILDING
12 ページ
-
MARINE EQUIPMENT
12 ページ
-
Husky Grease
9 ページ
-
Graco Pump Armo
9 ページ
-
Throat Seal Liquid
6 ページ
-
Fusion Gun Grease
9 ページ
-
HV-2000 Jet
24 ページ
-
G-Force™ II
4 ページ
-
PrecisionSwirl
8 ページ
-
EcoQuip 2 EQm
20 ページ
-
AirPro EFX™
8 ページ
-
AirPro™ Automatic
4 ページ
-
ILE Buyer?s Guide
144 ページ
-
Graco PMG Buyer's Guide
122 ページ
-
Flexible Packaging
4 ページ
-
filtration brochure
4 ページ
-
Graco Dispensit Brochure
12 ページ
-
Reactor® 2
16 ページ
-
Supply pumps
8 ページ
-
Finex air spray guns
2 ページ
-
300435Ej
64 ページ
-
340712Ea
8 ページ
-
320611Ea
4 ページ
-
XM Plural-Component
8 ページ
カタログアーカイブ
-
Probler Gun User Manual
32 ページ
-
APD User Manual
48 ページ
-
RTM Spartan II Brochure
48 ページ
-
RTM Spartan Brochure
44 ページ
-
MCG User Manual
48 ページ
-
Formula Gun User Manual
36 ページ
-
Indy Gel Brochure
2 ページ
-
G2 User Manual
36 ページ
-
Indy User Manual
40 ページ
-
Indy-X User Manual
44 ページ
-
Guardian A6 Brochure
4 ページ
-
Guardian A5 Brochure
2 ページ
-
MH User Manual
68 ページ
-
Brochure
14 ページ