Dedicated_to_quality
1 / 24ページ

{{requestButtons}}

カタログの抜粋

Dedicated_to_quality - 1

GLOBAL MARINE & OFFSHORE LIGHTING SOLUTIONS Dedicated to quality About quality assurance, test procedures and product certification in the Glamox Group

カタログの1ページ目を開く
Dedicated_to_quality - 2

Glamox is the leading supplier of lighting solutions to the world's marine and offshore markets. We take pride in providing products of superior technical quality that work reliably even under the most extreme conditions. Technology and expertise Our products and solutions are developed and tested by our engineers at our own research and testing facilities, and manufactured and certified in accordance with all relevant quality and environmental standards. They are based on the latest technology and expertise - and generations of experience. Our quality systems The Glamox Group's quality...

カタログの2ページ目を開く
Dedicated_to_quality - 3

The CE mark is a mandatory conformity marking for products sold in the European Economic Area (EEA). It is the manufacturer’s declaration that the product meets the requirements of the applicable EC directives. ENEC is the high quality European mark for electrical products that demonstrates compliance with European safety standards. The two-digit number indicates which certification body has issued the ENEC certification.

カタログの3ページ目を開く
Dedicated_to_quality - 4

Free fall shock tests 6 Salt mist spray test 16 Light data simulation 20 Modern testing facilities As a result of the high demands placed on the quality and durability of its products, the Glamox Group operates modern assessment and testing laboratories in Norway and Germany for the simulation of a wide variety of environmental conditions. Environmental test centers in Bremen and Molde These institutes have earned an excellent reputation in the lighting industry, and possess licenses from institutions such as the European Norms Electrical Certification (ENEC), the BSH Bundesamt fur...

カタログの4ページ目を開く
Dedicated_to_quality - 5

The laboratories in Bremen and Molde have been certified in accordance to the requirements of ISO 9001, ATEX and IECEx. Third party testing On account of their significance and their reliable simulation and testing methods, the laboratories are also used by external firms and organizations. The test reports of our laboratories are accepted e.g. by Germanischer Lloyd (GL), Lloyd’s Register (LR), Det Norske Veritas (DNV), Bureau Veritas (BV), Physikalisch-Technische Bundesanstalt (PTB) and many more. The importance of testing and simulations The simulations performed in our laboratories aim...

カタログの5ページ目を開く
Dedicated_to_quality - 6

Free fall shock tests Mechanical shock has the potential for damaging a product. For this reason there are shock resistance requirements based on a number of international standards, depending on a luminaire’s intended application and purpose. We test our luminaires in accordance with these requirements for type approval purposes. Sometimes a shock may result in only minor damage which may not be critical for use. However, cumulative minor damage from several shocks could eventually result in the product becoming unusable, or cause the service life of the product to be shortened. Therefore...

カタログの6ページ目を開く
Dedicated_to_quality - 7

Vibration testing Marine luminaires and luminaires with Ex approvals have to be vibration tested. We have equipment to do pre-qualifying tests for vibration. Within the scope of vibration testing, three different types of tests are performed: Sinusodial vibration, various shock tests and random testing. A slip table with an oil film is used to test products from impact with sinus, random and shock impulses. Acceleration sensors are used to investigate the behaviour of the test subject under the influence of vibration loading. Using the slip table, acceleration values of up to 15 G can be...

カタログの7ページ目を開く
Dedicated_to_quality - 8

Impact resistance in sub-zero environments In mechanics, an impact is a high force or shock applied over a short time period when two or more bodies collide. Impact tests are used in studying the toughness of material. A material’s toughness is a factor of its ability to absorb energy during deformation. Brittle materials have low toughness as a result of the small amount of deformation that they can endure. The impact value of a material can also change with temperature. Generally, at lower temperatures the impact energy of a material is decreased. Minus 50°C We test our luminaires with...

カタログの8ページ目を開く
Dedicated_to_quality - 9

Climatic testing Environmental simulations in climate test chambers allow us to measure the effects of temperature and humidity on our products in a controlled manner. Climatic testing is required to ensure that our luminaires will perform to standard under the climatic conditions they will encounter in service use. Materials can deteriorate over time, ageing prematurely due to either high or low temperature extremes, while humid conditions may lead to condensation which can be damaging to electronic components. Our climate test chambers have a test space of up to 1,500 litres. They are...

カタログの9ページ目を開く
Dedicated_to_quality - 10

Submersion into water The luminaires are tested against ingress of water in up to 1 meter depth. Water pressure tank The luminaires are submerged into a water pressure tank, simulating various depths beyond one meter. Spray water/splash water The luminaires are hosed with varying degrees of power, from fine spray to hard water jets. IP rating (water) In our wetrooms we assess the protection of our luminaires against ingress of water, varying over differing degrees of protection, depending upon the requirements for the different types of lighting product. From rain testing through spray...

カタログの10ページ目を開く
Dedicated_to_quality - 11

IP rating (dust) In our dust chambers we assess the protection of our luminaires against ingress of solid particles, varying over differing degrees of protection, depending upon the requirements for the different types of lighting product. Solid objects protection There are six levels of protection against the ingress of solid foreign objects, represented by the first digit in the two-digit IP rating of a product. > 50mm: Any large surface of the body, such as the back of a hand, but no protection against deliberate contact with a body part >12.5 mm: Fingers or similar objects > 2.5 mm:...

カタログの11ページ目を開く
Dedicated_to_quality - 12

Electromagnetic compatibility testing (EMC) EMC testing All electrical products are potential emitters of electromagnetic waves. Our luminaires are tested according to both EN-55015 and EN-61547. GTEM cell In a GTEM cell we can measure a product's immunity to HF radiation and radio emissions. EU directives set requirements to which norms equipment of any kind have to be satisfied before released for the EU market. Therefore all electric equipment must satisfy the EMC-directive. This EU directive refers to European product norms EN-55015 (electromagnetic interference from a luminaire)...

カタログの12ページ目を開く

GLAMOX ASAのすべてのカタログとパンフレット

  1. E80-S

    2 ページ

  2. E80-R(M)

    3 ページ

  3. EL40

    3 ページ

  4. DL40-R108A

    4 ページ

  5. DL40-R92A

    4 ページ

  6. DL40-R70A

    4 ページ

  7. DL40-R70F

    4 ページ

  8. DL41-R155

    2 ページ

  9. DL42-R77

    3 ページ

  10. TL60N MIL

    1 ページ

  11. FL70

    5 ページ

  12. MIL LED

    2 ページ

  13. DLT RS (M) LED

    4 ページ

  14. TX65

    2 ページ

  15. Panel heater

    3 ページ

  16. FL60 LED

    4 ページ

  17. L-1

    2 ページ

  18. AL60-Cabin

    3 ページ

  19. TX61 LED

    4 ページ

  20. AL61-SQ

    3 ページ

  21. MIX LED

    2 ページ

  22. E20 G2

    2 ページ

  23. 1448

    5 ページ

  24. TL44-S

    3 ページ

  25. TL14 LED

    4 ページ

  26. AL42-W-LED

    3 ページ

  27. HX55

    6 ページ

  28. TX60

    6 ページ

  29. Wind Energy

    2 ページ

  30. MAX KIT LED

    6 ページ

  31. TX61

    6 ページ

  32. AL60/AL61

    24 ページ

  33. AL60-W

    3 ページ

  34. AL60-SQ

    5 ページ

  35. AL60-SC

    4 ページ

  36. FL40 LED

    2 ページ

  37. 1445 with LEDs

    2 ページ

  38. Xenon 3000W

    3 ページ

  39. TX20 / TX21

    4 ページ

  40. E80 / E85

    16 ページ

  41. FL60

    2 ページ

  42. Max ice

    4 ページ

  43. MIR LED

    8 ページ

  44. Helideck lighting

    16 ページ

  45. TL60

    8 ページ

  46. Series 65

    8 ページ

  47. cruise and ferry

    16 ページ

  48. FX60

    6 ページ

  49. DL60 LED

    8 ページ

  50. SL40 R5

    4 ページ

  51. R10

    2 ページ

  52. Xenon searchlight

    3 ページ

  53. R20

    2 ページ

  54. XENON BL Bowlight

    2 ページ

  55. TL11-R250

    2 ページ

  56. TINA_

    2 ページ

  57. MIX

    2 ページ

  58. MIR_T8_IP54

    2 ページ

  59. MIR_T8_IP_67

    2 ページ

  60. MAX

    2 ページ

  61. GTX

    2 ページ

  62. GFX

    2 ページ

  63. GFBT

    1 ページ

  64. GEF

    1 ページ

  65. DLT_RT_FR

    2 ページ

  66. C10_W

    2 ページ

  67. UL / CSA Products

    124 ページ

カタログアーカイブ

  1. Explore Lighting

    11 ページ