Instruction Bulletin No. 198938 Rev A In-Line Flow Switches FS-380P Series Installation All NPT threads should be installed using a suitable thread sealant (Teflon tape or Permatex “No more Leaks”). Sealant must be kept out of unit during installation. Ten diameters of straight run piping are recommended upstream and downstream of the flow sensor. Body End Fitting Inlet Outlet Spring Specifications Wetted Materials Housing, End Fitting Piston Hydrolytically Stable Glass Reinforced Polypropylene PPS Composite 316 Stainless Steel Spring O-Ring Fluorcarbon 200 PSI at 70°F, 100 PSI at 212°F Oper. Pressure, Max. Operating Temperature FS-380P Flow Switches Can be Mounted In Various Positions Flow settings are based on a vertical position (inlet port down), using water at +70°F on increasing flow. Some variation in set point actuation will occur in other mounting orientations. -20°F to +212°F (100°C) 100 Micron or Better Required Filtration Set Point Accuracy Set Point Differential Switch, See “Switch Ratings” Inlet / Outlet Electrical Termination ±20%, Maximum 20% Maximum SPST, 10 VA 3/8” NPT Male or Quick Connect No. 24 AWG, 24” to 26” Polymeric Leads Note: The FS-380P is UL and CSA approved. Pressure Drop - Typical 16 14 Switch Ratings PSI Drop 12 Contact rating: 10W Switching Voltage (DC or AC Peak): 200 Max. Switching Current (DC or AC): 0.4 A Max. Carry Current (DC or AC): 0.4 A Max. Break down Voltage: 230 VDC Min. 10 8 6 4 Wiring Diagram 2 Normally Open 0 0 1 2 3 4 5 Flow Rate - GPM 6 7 8

カタログの1ページ目を開く
FS-380P Series - 2

Dimensions 11/16” Hex. 3/8” NPT Ports 1” (25 mm) 4” (102 mm) 1” (25 mm) 11/16” Hex. O-Ring Typ. Quick Disconnect Ports .75” (19 mm) Across Flats .43” (11 mm) Dia. Typ. 4.22” (107 mm) Important Points: • Gems products must be maintained and installed in strict accordance with the National Electrical Code and the applicable Gems product instruction Bulletin that covers installation, operation and proper maintenance. Failure to observe this information may result in serious injury or damages. • For hazardous area applications involving such things as, but not limited to, ignitable mixtures,...

カタログの2ページ目を開く

Gems Sensorsのすべてのカタログとパンフレット

  1. PM/PL Series

    2 ページ

  2. 3600 Series

    4 ページ

  3. 3800 Series

    2 ページ

  4. 3500 Series

    4 ページ

  5. F Series

    4 ページ

  6. Pressure Transducers

    67 ページ

  7. Pressure Switches

    30 ページ

  8. Flow Switches

    26 ページ

  9. Solenoid Valves

    40 ページ

  10. Flow Sensors

    13 ページ

  11. Electronic_Products-

    13 ページ

  12. Flow_Switches

    24 ページ

  13. Pressure_Switches

    28 ページ

  14. SemiconBroch

    8 ページ