
カタログの抜粋

United States Pagel www.EatonElectrical.com Eaton Electrical ine General Specifications 1000 Cherrington Parkway fof fhe Hatteras Light All Power Pedestals Must Meet the Following: A. Shall be tested and certified to be in compliance with ANSI/UL® 231 entitled "power outlets." B. If a laboratory other than UL is used, that laboratory must certify, in writing, that the power outlet has been tested and meets all of the requirements of ANSI/UL 231, including 746C polymeric materials, and that the unit will pass the 94VO-5V flame test. C. Shall be certified to meet all sections of NFPA® 303, Fire Protection Standards for Marinas and Boatyards - 2006 Edition. D. Shall meet 406.8 (B)(2)(a) of the National Electrical Code® NFPA 70, i.e., "A receptacle installed in a wet location shall be installed in a weatherproof enclosure, the integrity of which is not affected when the attachment plug cap is inserted." E. The receptacles shall be mounted at a down angle of 35 degrees or greater from vertical to relieve the strain of the cable weight on the receptacle locking mechanism. 2.1 Acceptable Manufacturers — Power Pedestals/Hatteras Light Enclosures Marina Power and Lighting 2.2 Power Pedestals/Hatteras Light Enclosures — General 1. The housing shall be constructed of 1/4" thick injection molded resin material and shall be coated with a UV-resistant polyurethane. It shall be UL listed as a type 3R weatherproof 1. The power pedestal shall be completely pre-wired at the factory to the load side of the compression lug assembly. 2. All load copper wiring shall be of high stranding and tin-plated 3. The maximum size of the line wiring shall be # 2/0 AWG direct feed or #1 loop feed. C. Loop Feed Bus Bar System: 1. The bus system shall be a 1/4" - 20 silicon-bronze stud with a silicon-bronze Belleville type washer. The 1/4" - 20 silicon- bronze hex-nut shall be torqued to 100 inch-pounds with a maximum wire size of 2/0 AWG. 2. Double Barrel Mechanical Lugs (Optional) — rated for copper 1. All exposed metallic parts must have an integral ground that is a part of the equipment grounding system. 1. All receptacles shall be of the corrosion resistant type con- forming to NEMA® L - 5 and/or NEMA L - 6 requirements and are rated for marine use. 100 amp receptacles should conform 2. All receptacles shall be mounted at an angle that is a mini- mum 35 degrees from vertical and located behind a lockable weatherproof hinged door that is under tension to ensure proper closing pressure when the receptacle is or is not 3. All receptacles shall be mounted at least 24" above the dock. 1. All breakers for receptacles shall be of the thermal-magnetic type, 10,000 AIC, and shall be UL listed. 1. Receptacles for boat users shall be a locking and grounding type, either single-phase, 125 volt 30 amp and/or 50 amps, and/or 125/250 volt 50 amps. 1. Each pedestal shall be equipped with a non-metered light. The light shall be a 13 watt fluorescent biaxial light that is controlled by an electromechanical photocell. 2. The light shall provide 360 degree dock illumination such that ndirect lighting extends from station to station with a mini- mum dock lighting of one foot candle at 15'. The lighting shal not interfere with boaters' navigation. 1. Circuit breakers for 30 amp receptacles shall be a single-pole, 125 volt, 30 amp thermo-magnetic type. 2. Circuit breakers for 50 amp receptacles shall be a single pole 125 volt 50 amp, or two-pole 125/250 volt 50 amp thermo- magnetic type.
カタログの1ページ目を開く
United States Eaton Electrical ine General Specifications 1000 Cher ngton Parkway fof fhe Hatteras Lignt 1. The pedestal can be equipped with one fully electronic meter that displays the kilowatt-hours used by the pedestal on a non-resettable digital counter that is protected from the weather. The accuracy of the meter must be certified by the manufacturer to have a 125 ampere rating and no more than a 2% error when tested in accordance with a ANSI-C12.1. E. Telephone and Cable TV (Optional): 1. Each pedestal can be equipped with one outlet. Each outlet shall contain a marine telephone...
カタログの2ページ目を開くEatonのすべてのカタログとパンフレット
-
PowerXL DE1 Catalog
6 ページ
-
Lighthouse SS®
2 ページ
-
Lighthouse®
2 ページ
-
Hatteras Light®
2 ページ
-
Newport Harbor Mate
2 ページ
-
Parts Catalog 2018
42 ページ
-
Solar OEM
43 ページ
-
Conveyor sensor systems
30 ページ
-
Utility solutions
7 ページ
-
Oil & gas solutions
9 ページ
-
Mining solutions
5 ページ
-
Land-based drilling
24 ページ
-
LED Lighting
1 ページ
-
Smart Start Pedestal
1 ページ
-
DeckHand
2 ページ