Ballast Water Management Technologies: A Comparison Between UV based Systems & Electrochlorination Systems This white paper provides an overview of the two most prominent ballast water management (BWMS) technologies installed on today’s vessels-ultraviolet (UV)-based systems and electrochlorination (EC) systems. It offers a comparison between the two technologies and explores the benefits and challenges faced by their operators. In particular this white paper puts spotlight on the so far overlooked but potentially serious complications related to operating UV BWMS with different operating...
カタログの2ページ目を開く
Up until October 2019, close to 10,000 vessels— nearly 10% of the global vessel fleet—has been fitted with a ballast water management (BWM) system. According to Clarkson's World Fleet Register, the most common technologies for BWM are ultraviolet (UV)-based systems and electrochlorination (EC) systems. Figure 1 shows the different technologies installed on vessels. The IMO guidelines for type approval of BWM systems were revised in October 2018. Since the revision, the IMO now states that type approval according to the new BWM system code MEPC.300(72) (also referred to as the revised G8) is...
カタログの3ページ目を開く
What is UV dose? The UV dose depends on the UV intensity (UV-I) and exposure time, and is simply defined as the product between these two parameters. UV-I measures how much light (or energy) reaches a given measurement point. Most UV systems measure the UV-I, but the systems can vary considerably in terms of the UV lamp being used and the sensor setup. In particular, the distance between the sensor and the UV lamp influences the measured UV-I. For this reason, UV-I values shouldn’t be used to compare systems. Fortunately, another measurement called UV-transmission (UV-T), can be used to...
カタログの4ページ目を開く
Table 1: Bulk Carrier Operating Profile the IMO mode, because US mode will typically mean reduced flow, which leads to longer ballast operation and hence longer port stay. However, if the IMO mode is used during ballast operation, but then later on it is determined that the ballast water shall be discharged in the US, the ballast water will be non-compliant and must be treated as such. This means the local port state authorities in the US must be contacted and an agreement about what to do must be reached. This could be a requirement that the vessel must conduct a full ballast water...
カタログの5ページ目を開く
CompactClean does not apply flow reduction to meet USCG discharge standards. But other, slightly lower power-consuming BWM systems as the one in this example, typically apply a 50% reduction in flowrate when ballasting and de-ballasting in US mode. In this example, it means the time required for ballasting and de-ballasting in one year would Ambient sea water is pumped through the ejector as drive water. Pre-treated ballast water stripped by the ejector is combined with the ambient sea water and the combined stream is pumped through the UV chamber for treatment. Another version of this...
カタログの6ページ目を開く
Table 2: Neutralization chemical costs Electrochlorination systems offer cost-effective solutions on high ballast-flow vessels (i.e., flows above 1500 m3/h) with limited power availability. Electrochlorination describes the generation of hypochlorite from saltwater electrolysis. It can be divided into two main types: in-line (Figure 4), and side-stream (Figure 5). Both types of electrochlorination typically combine mechanical filtration with treatment with chlorine, which is produced by an electrolysis unit. For side-stream technologies, approximately 1-2% of total ballast water flows to...
カタログの7ページ目を開く
Table 3: Power consumption cost of fuel oil The figures in Table 3 indicate a yearly cost of power consumption of 1,400.00 EUR, resulting in a combined cost of 10,300.00 EUR, without including costs for spare parts, cleaning chemicals, or heating requirements when operating in colder climates. Treating the same amount of ballast water (i.e., 552,000 m3) with a CompactClean-1000 system costs approximately 8,300.00 EUR in fuel oil, whereas the minimum power consumption corresponds to a total fuel of cost of just 3,100.00 EUR. The OPEX alone is worth considering and clearly indicates that...
カタログの8ページ目を開く
Summary In general filtration + UV-treatment is a very simple and well known technology, and with no by-products produced. UV-treatment BWM systems are considered CAPEX competitive for flowrates up to 1,000 - 1,500 m3/h. Their performance is not affected by water salinity or temperature, but is dependent on the UV-transmission of the ballast water. It is to be noted that UV BWM systems require treatment both during uptake and discharge, and under US regulations they are subject to minimum hold time restrictions. deep knowledge and we understand that not all type of technologies, systems...
カタログの9ページ目を開くDesmiのすべてのカタログとパンフレット
-
SPATE PD 75
2 ページ
-
Ro-Fence
2 ページ
-
Globeboom
6 ページ
-
SMART Boom
2 ページ
-
CompactClean
20 ページ
-
DESMI FineFog™
8 ページ
-
ESL & ESLH
2 ページ
-
MARINE & OFFSHORE
20 ページ
-
NSLV & NSLH
4 ページ
-
TERMITE
2 ページ
-
TERMINATOR
2 ページ
-
TARANTULA
2 ページ
-
RO-BOOM Speed Sweep
2 ページ
-
RO-BOOM BEACH 800
2 ページ
-
RO-BOOM 3200
2 ページ
-
RO-BOOM 2200
2 ページ
-
RO-BOOM 2000
2 ページ
-
RO-BOOM 1800
2 ページ
-
RO-BOOM 1500
2 ページ
-
RO-BOOM 1300
2 ページ
-
RO-BOOM 1100
2 ページ
-
RO-BOOM 1000
2 ページ
-
RO-BOOM 650
2 ページ
-
POLLUTANK
2 ページ
-
POLLKITTEN
2 ページ
-
POLLCRAFT
2 ページ
-
POLLCAT
2 ページ
-
POLAR BEAR
2 ページ
-
OIL FENCE
2 ページ
-
HELIX SKIMMER
2 ページ
-
GIANT OCTOPUS
2 ページ
-
DOP 250 DUAL
2 ページ
-
DOP 200 DUAL
2 ページ
-
DOP 160
2 ページ
-
DESMI BOOM
2 ページ
-
DBD 40 SKIMMER
2 ページ
-
DBD 20 SKIMMER
2 ページ
-
DBD 16 SKIMMER
2 ページ
-
DBD 13-4 SKIMMER
2 ページ
-
DBD 5 SKIMMER
2 ページ
-
DBD 2 SKIMMER
2 ページ
-
CS BOOM
4 ページ
-
ALLIGATOR
2 ページ
-
A-BOOM
2 ページ
-
ROTAN PD
2 ページ
-
ROTAN HD
2 ページ
-
ROTAN ED
2 ページ
-
ROTAN GP
2 ページ
-
ROTAN CD
2 ページ
-
Spare Parts Kits
2 ページ
-
Vertical Pumps DP
8 ページ
-
VAC
2 ページ
-
SA
2 ページ
-
PVLN
2 ページ
-
NSLV/H
4 ページ
-
NSL- Stainless Steal
4 ページ
-
NSL
4 ページ
-
NSA
1 ページ
-
Modular S
2 ページ
-
Modular H
1 ページ
-
ESL
2 ページ
-
DSL
2 ページ
-
DESLUBE
1 ページ
-
Cargo Pumps
8 ページ
-
Pumps For Free
2 ページ
-
OptiPower
8 ページ
-
Commissioning
4 ページ
-
AquaCulture
12 ページ
-
Automation Solutions
12 ページ
-
DESMI Scrubber Pumps
8 ページ
-
DESMI AfterSales
12 ページ
-
Engine Room Pumps
16 ページ
-
Marine
20 ページ
-
DESMI KaziCat
4 ページ
-
DESMI Grafter
4 ページ
-
Lease Hire Equipment
2 ページ
-
Industrial Skimmers
2 ページ
-
Oilfence
2 ページ
-
Arctic Range
16 ページ
-
Speed-Sweep system
2 ページ
-
DESMI Article Collection
56 ページ
-
Company Profile
24 ページ