Product Data OMNIZONE™ 09AW001-064,AZ006-024 Air-Cooled Condensers 1 to 60 Nominal Tons Air-Cooled Condensers for Remote System Application. Several sizes to choose from with: • Standard or low sound motor • Proven performance in every building application • Efficient direct-drive fans • Cabinet designs in vertical and horizontal airflow configurations to meet a variety of application requirements • Small compact footprints for installation in tight spaces • A choice of factory-installed options that allow application customizing • High-efficiency performance for commercial and industrial projects • Available with R-410A, R-22 and R-134a refrigerant TYPICAL 09AWH012 UNIT Features/Benefits A family of ruggedly built condensers ideal for clinics, motels, schools, apartment and office buildings, and factories. Design flexibility Carrier remote condensers provide the design flexibility required in replacement, renovation, and new construction. Units are available in sizes from 1 to 60 tons. These condensers meet the needs for cooling restaurants, retail stores, warehouses, offices, and building additions.

カタログの1ページ目を開く
OMNIZONE 09AW001-064,AZ006-024 Air-Cooled Condensers - 2

Features/Benefits (cont) Flexibility in meeting job requirements is ensured with unit design and available factory options. The compact footprint saves valuable space and allows installation in tight locations. Matching condensers to existing indoor units is easy with a selection of coil circuiting. These units can be installed in vertical or horizontal airflow configurations, allowing greater flexibility to meet job requirements. Units may also be used with several different refrigerants. Units are available in all popular single or threephase voltages and with factorymounted control...

カタログの2ページ目を開く
OMNIZONE 09AW001-064,AZ006-024 Air-Cooled Condensers - 3

Model number nomenclature 09 AW H 012 V E - 6 0 1 A Factory Options A – Aluminum Cabinet B – Fused Disconnect†† C – 24 Volt Transformer D – Aluminum Cabinet, Fused Disconnect†† E – Aluminum Cabinet, 24 Volt Transformer F – Fused Disconnect, 24 Volt Transformer†† G – Aluminum Cabinet, Fused Disconnect, 24 Volt Transformer†† OMNIZONE ™ 09 – Remote Air-Cooled Condenser AW – Direct-Drive General Purpose Configuration H – Horizontal, Standard Motor V – Vertical, Standard Motor* L – Horizontal, Low Sound Motor W – Vertical, Low Sound Motor* Nominal Heat Rejection Size Tons Size Tons 001 – 1 012 –...

カタログの3ページ目を開く
OMNIZONE 09AW001-064,AZ006-024 Air-Cooled Condensers - 4

Model number nomenclature (cont) 09 AZ H 012 V A - 3 0 1 A OMNIZONE ™ 09 – Remote Air-Cooled Condenser Factory Options A – Aluminum Cabinet B – Fused Disconnect†† D – Aluminum Cabinet, Fused Disconnect†† F – Fused Disconnect, 24 Volt Transformer†† AZ – Direct-Drive (Sized to Work Best with 50XC) Configuration H – Horizontal, Standard Motor V – Vertical, Standard Motor* L – Horizontal, Low Sound Motor W – Vertical, Low Sound Motor* Nominal Heat Rejection Size Tons Size Tons 006 – 5 014 – 12 008 – 7-1/2 016 – 15 024 – 20 012 – 10 Motor Control Option - – Open Drip Proof (ODP) with Contactors...

カタログの4ページ目を開く
OMNIZONE 09AW001-064,AZ006-024 Air-Cooled Condensers - 5

AHRI* capacities NOMINAL TONS *Air-Conditioning, Heating and Refrigeration Institute. NOTES: 1. Based on a temperature difference of 30° F. 2. ARI rating condition with R-410A is 95 F air entering the condenser, 125 F saturated condensing temperature, charged to nominal system charge per installation instructions for 5° F of subcooling. 3. Units are only AHRI rated when used as part of a system with 50XCR units (such as 50XCR with matching 09AZ air-cooled condenser models). AHRI ratings do not exist for the 09AW,AZ condensers alone.

カタログの5ページ目を開く
OMNIZONE 09AW001-064,AZ006-024 Air-Cooled Condensers - 6

Physical data UNIT NOIMNAL RATING (Tons) OPERATING WEIGHT (lb) SHIPPING WEIGHT (lb) REFRIGERANT NOM HEAT REJECTION (MBtuh)* FAN Quantity Prop. Diameter (in.) Rpm Total Airflow (cfm) Motor Hp (per fan)† COIL UNIT NOMINAL RATING (Tons) OPERATING WEIGHT (lb) SHIPPING WEIGHT (lb) REFRIGERANT NOM HEAT REJECTION (MBtuh)* FAN Quantity Prop. Diameter (in.) Rpm Total Airflow (cfm) Motor Hp (per fan)† COIL May be mounted Vertical or Horizontal 1 8 4.34 1 Cu Tube/Al Fin or Cu Tube/Cu Fin or Cu Tube with Coated Fin Arrangement Rows Fins/in. Total Face Area (sq ft) Number of Circuits Subcooler...

カタログの6ページ目を開く
OMNIZONE 09AW001-064,AZ006-024 Air-Cooled Condensers - 7

NOMINAL RATING (Tons) OPERATING WEIGHT (lb) SHIPPING WEIGHT (lb) REFRIGERANT NOM HEAT REJECTION (MBtuh)* FAN Quantity Prop. Diameter (in.) Rpm Total Airflow (cfm) Motor Hp (per fan)† COIL Arrangement Rows Fins/in. Total Face Area (sq ft) Number of Circuits Subcooler CONNECTIONS (in.)** Hot Gas Single Circuit Liquid Hot Gas Dual Circuit Liquid NOMINAL RATING (Tons) OPERATING WEIGHT (lb) SHIPPING WEIGHT (lb) REFRIGERANT NOM HEAT REJECTION (MBtuh)* FAN Quantity Prop. Diameter (in.) Rpm Total Airflow (cfm) Motor Hp (per fan)† COIL Arrangement Rows Fins/in. Total Face Area (sq ft) Number of...

カタログの7ページ目を開く
OMNIZONE 09AW001-064,AZ006-024 Air-Cooled Condensers - 8

Physical data (cont) NOMINAL RATING (Tons) SHIPPING WEIGHT (lb) REFRIGERANT NOM HEAT REJECTION (MBtuh)* FAN Quantity Prop. Diameter (in.) Rpm Total Airflow (cfm) Motor Hp (per fan) COIL Arrangement Rows Fins/in. Total Face Area (sq ft) Number of Circuits Subcooler CONNECTIONS (in.) Hot Gas Single Circuit Liquid Hot Gas Dual Circuit Liquid LEGEND MBtuh — Btuh in Thousands *Heat rejection is based on R-410A 25 F temperature difference from saturated discharge temperature to entering-air temperature. NOTE: When selecting R-134a as a refrigerant, divide required capacity by 0.95 to determine...

カタログの8ページ目を開く
OMNIZONE 09AW001-064,AZ006-024 Air-Cooled Condensers - 9

Factory-installed options Coil fin treatment options Motor control options Coils may be supplied with copper, pre-coated or e-coated fins, to provide optimum corrosion resistance in a variety of applications. Factory-installed controls can provide 24-volt operated fan contactors and fan cycling control 2-fan units (include fan contactor). Speed control fan cycling control modulates fan speed to maintain minimum condensing pressure for operational temperatures as low as –20 F. Factory mounted on lead fan motor fan cycling and fan contacts are also provided on two-fan units. Circuiting...

カタログの9ページ目を開く