video corpo

Wärtsilä Auxpac Product Guide - 120 Pages

  1. P. 1

  2. P. 2

  3. P. 3

  4. P. 4

  5. P. 5

  6. P. 6

  7. P. 7

  8. P. 8

  9. P. 9

  10. P. 10

  11. P. 20

  12. P. 30

  13. P. 40

  14. P. 50

  15. P. 60

  16. P. 70

  17. P. 80

  18. P. 90

  19. P. 100

Catalogue excerpts

WÄRTSILÄ AUXPAC PRODUCT GUIDE

 Open the catalogue to page 1

Wärtsilä Auxpac - Product Guide Introduction Introduction This Product Guide provides data and system proposals for the early design phase of marine engine installations. For contracted projects specific instructions for planning the installation are always delivered. Any data and information herein is subject to revision without notice. This 1/2011 issue replaces all previous issues of the Wärtsilä Auxpac Project Guides. Issue Wärtsilä Auxpac portfolio updated, IMO Tier 2 gensets added and other minor updates. Auxpac gensets 1400W8L20 and 1700W9L20 added, Compact Silencer System added, chapter...

 Open the catalogue to page 3

Wärtsilä Auxpac - Product Guide Table of Contents Product Guide Auxpac - 1/2011

 Open the catalogue to page 4

Wärtsilä Auxpac - Product Guide Table of Contents Product Guide Auxpac - 1/2011

 Open the catalogue to page 5

Wärtsilä Auxpac - Product Guide This page intentionally left blank Product Guide Auxpac - 1/2011

 Open the catalogue to page 6

Wärtsilä Auxpac - Product Guide 1. Main Data and Outputs Main Data and Outputs Wärtsilä Auxpac – reliable and cost-efficient power generation The WÄRTSILÄ® Auxpac is a generating set designed for auxiliary power generation in commercial type vessels. It is a pre-commissioned standard package that ensures the availability of electrical power in sufficient quantity as and when it is needed. Wärtsilä Auxpac is designed to provide: • Easy installation Easy operation The Wärtsilä Auxpac’s are the ideal choice for Container vessels, Bulk carriers, General cargo vessels and Tankers. Technical main data...

 Open the catalogue to page 7

Wärtsilä Auxpac - Product Guide 1. Main Data and Outputs 1.2.3 Maximum continuous output Table 1.1 Rating table for Wärtsilä Auxpac gensets Output [kWe] Voltage [V] Generator Permissible overload is 10% for one hour every twelve hours. Maximum fuel rack position is mechanically limited to 110% continuous output. Reference conditions The output is available up to a charge air coolant temperature of max. 38°C and an air temperature of max. 45°C. For higher temperatures, the output has to be reduced according to the formula stated in ISO 30461:2002 (E). The specific fuel oil consumption is stated...

 Open the catalogue to page 8

Wärtsilä Auxpac - Product Guide 1. Main Data and Outputs Principal dimensions and weights Figure 1.1 Wärtsilä Auxpac dimensions (DAAE026184e) Table 1.2 Wärtsilä Auxpac 900 rpm / 60Hz Type Table 1.3 Wärtsilä Auxpac 1000rpm / 50Hz Type Dimensions in mm. Weight in tons. Weight including resilient elements. Tolerance = ± 3% Product Guide Auxpac - 1/2011

 Open the catalogue to page 9

Wärtsilä Auxpac - Product Guide 2. Operating Conditions Operating Conditions Loading capacity 2.1.1 Loading rate The loading rate of a highly turbocharged diesel engine must be controlled, because the turbocharger needs time to accelerate before it can deliver the required amount of air. Class rules regarding load acceptance capability stipulate what the generating set must be capable of in an unexpected situation, but in normal operation the loading rate should be slower, about 60 seconds from zero to full load. The generating set can be loaded immediately after start, provided that the engine...

 Open the catalogue to page 10

Wärtsilä Auxpac - Product Guide 3. Technical Data Technical Data Wärtsilä Auxpac 645W4L20 / 60 Hz IMO Tier 2 with VIC Note 5) Engine speed Engine output Mean effective pressure Combustion air system Flow of air at 100% load Temperature at turbocharger intake, max Temperature after air cooler (TE 601) Temp. after turbocharger at 100% load (TE 517) Temp. after turbocharger at 85% load (TE 517) Calculated exhaust diameter for 35 m/s Jacket water Exhaust gas system (Note 1) Heat balance at 100% load (Note 2) Fuel system (Note 3) Pressure before injection pumps (PT 101) Pressure before injection pumps,...

 Open the catalogue to page 11

Wärtsilä Auxpac - Product Guide 3. Technical Data Wärtsilä Auxpac 645W4L20 / 60 Hz IMO Tier 2 with VIC Note 5) Pressure at engine, after pump, nom. (PT 451) Pressure at engine, after pump, max. (PT 451) Temperature before engine (TE 451) Capacity of engine driven pump, nom. Pressure drop over charge air cooler Pressure drop over thermostatic valve Pressure drop over oil cooler Pressure drop in the external system, max. Pressure from expansion tank Air consumption, start (remote) Generator data (Note 4) Generator brand Rated output Rated current Power factor Temperature rise Insulation class Heat...

 Open the catalogue to page 12

Wärtsilä Auxpac - Product Guide 3. Technical Data Wärtsilä Auxpac 975W6L20 / 60 Hz IMO Tier 2 with VIC Note 5) 1050W6L20 / 60 Hz IMO Tier 2 with VIC Note 5) 1400W8L20 / 60 Hz IMO Tier 2 with VIC Note 5) Engine speed Engine output Mean effective pressure Combustion air system Flow of air at 100% load Temperature at turbocharger intake, max Temperature after air cooler (TE 601) Temp. after turbocharger at 85% load (TE 517) Calculated exhaust diameter for 35 m/s Jacket water Exhaust gas system (Note 1) Temp. after turbocharger at 100% load (TE 517) Heat balance at 100% load (Note 2) Fuel system (Note...

 Open the catalogue to page 13

Wärtsilä Auxpac - Product Guide 3. Technical Data Wärtsilä Auxpac 975W6L20 / 60 Hz IMO Tier 2 with VIC Note 5) 1050W6L20 / 60 Hz IMO Tier 2 with VIC Note 5) 1400W8L20 / 60 Hz IMO Tier 2 with VIC Note 5) Pressure drop in the external system, max. Pressure from expansion tank Air consumption, start (remote) Generator data (Note 4) Generator brand Rated output Rated current Power factor Temperature rise Insulation class Ta Heat dissipation of air cooled generator ISO-optimized engine at ambient conditions according to ISO 3046/1. With engine driven pumps. Fuel net caloric value: 42700 kJ/kg. Radiation...

 Open the catalogue to page 14

Wärtsilä Auxpac - Product Guide 3. Technical Data Wärtsilä Auxpac 1600W9L20 / 60 Hz IMO Tier 2 with VIC Note 5) Engine speed Engine output Mean effective pressure Combustion air system Flow of air at 100% load Temperature at turbocharger intake, max Temperature after air cooler (TE 601) Exhaust gas system (Note 1) Flow at 100% load Temp. after turbocharger at 85% load (TE 517) Calculated exhaust diameter for 35 m/s Jacket water Temp. after turbocharger at 100% load (TE 517) Heat balance at 100% load (Note 2) Fuel system (Note 3) Pressure before injection pumps (PT 101) Pressure before injection...

 Open the catalogue to page 15

All Wärtsilä Corporation catalogues and brochures

  1. Wärtsilä 3C

    8 Pages

    En
  2. PROPULSION SYSTEMS

    16 Pages

    En
  3. Xvintage

    13 Pages

    En
  4. IMC ferries

    4 Pages

    En
  5. Wartsila-O-E-W-MS

    20 Pages

    En

Archived catalogues

  1. Water Jet Drives

    12 Pages

    En
  2. Auxpac

    8 Pages

    En
  3. 50DF

    16 Pages

    En
  4. 26-46 Series

    12 Pages

    En
  5. 20 Series

    16 Pages

    En
  6. RT-flex58T

    24 Pages

    En
  7. RT-flex60C

    28 Pages

    En
  8. RTA68

    24 Pages

    En
  9. RT-flex82C

    4 Pages

    En
  10. RT-flex82T

    4 Pages

    En
  11. RTA84T

    24 Pages

    En
  12. RTA96C

    24 Pages

    En