TEST EQUIPMENT FOR PRESSURE AND TEMPERATURE SENSORS PRODUCT AT A GLANCE Sensors are vital for an engine to function properly and should be tested on a regular basis. To facilitate the testing procedure, Wärtsilä has developed a new sensor test set which includes all equipment needed for testing pressure and temperature sensors on Wärtsilä engines. The set includes calibrators and adaptors for different sensor models. All comes in a rigid lightweight storage case for convenient transportation and handling. PNEUMATIC PRESSURE AND VACUUM HAND PUMP • Pressure source: 40 bar gauge and vacuum –960 mbar • Pressure adjustment: Adjustable stroke and inbuilt fine control DRY BLOCK TEMPERATURE CALIBRATOR • Temperature range: +30 °C to +350 °C • Five pieces of different inserts to cover the range of temperature sensors used on Wärtsilä engines • Power supply: 230 V AC, 50/60 Hz STORAGE CASE • Crush-proof, dust-proof and watertight according to IP67 • Open cell core and solid wall construction • Orange colour with special cut interior • Exterior dimensions: 50 × 40 × 18 cm • Weight with tools: 9.6 kg DIGITAL PRESSURE TEST GAUGE • Pressure range: 0–70 bar gauge • Accuracy: 0.05% FS • Power supply: 9 V alkaline battery • Pressure media: Fluids compatible with stainless steel MULTIFUNCTION CALIBRATOR • Sources and reads mA, mV, V, ohms, frequency and pulses • Simulates and reads 8 RTD and 12 thermocouple types • Simultaneous dual reading capability • 24 V loop power supply • Robust and weatherproof • Power supply: 3 × AA alkaline batteries See overleaf for technical data.

 Open the catalogue to page 1

MULTIFUNCTION CALIBRATOR Cold Junction (CJ) compensation Automatic/manual Automatic/manual Communications port 250 Ω series resistor. Use this instrument together with a HART® communicator to set up and calibrate HART® devices. Other functions hold, backlight Range (measure) Accuracy (measure) mA 0.02% of reading + 3 counts mV 0.02% of reading + 2 counts V 0.03% of reading + 2 counts Range (supply) Accuracy (supply) Temperature coefficient (measure or supply) Four 4 mm sockets One TC mini-connector socket Range (measure) Accuracy (measure) mA 0.02% of reading + 3 counts V 0.03% of reading + 2...

 Open the catalogue to page 2

All Wärtsilä Corporation catalogues and brochures

  1. Wärtsilä 3C

    8 Pages

    En
  2. PROPULSION SYSTEMS

    16 Pages

    En
  3. Xvintage

    13 Pages

    En
  4. IMC ferries

    4 Pages

    En
  5. Wartsila-O-E-W-MS

    20 Pages

    En

Archived catalogues

  1. Water Jet Drives

    12 Pages

    En
  2. Auxpac

    8 Pages

    En
  3. 50DF

    16 Pages

    En
  4. 26-46 Series

    12 Pages

    En
  5. 20 Series

    16 Pages

    En
  6. RT-flex58T

    24 Pages

    En
  7. RT-flex60C

    28 Pages

    En
  8. RTA68

    24 Pages

    En
  9. RT-flex82C

    4 Pages

    En
  10. RT-flex82T

    4 Pages

    En
  11. RTA84T

    24 Pages

    En
  12. RTA96C

    24 Pages

    En