It switches on all the warning
lights for boats and all the display segments. Test N° 5 [t5] >
8 - HIDDEN PARAMETERS
T It switches on and off three times the valve/resistance
relay for boats (once per second). Then
it sets up the fan at medium speed (F2) and switches on again the valve/resistance
relay for 5 minutes. During the test the message [t.H] appears on the display. est with a Comp act/S plit unit Test ALL[ALL] The test ALLsets up the tests sequence t1-t2-t3-t4-t5. Test N° 1 [t1] It sets up the fan and commutes the four speeds to a sequence (20 seconds for each
one). The abbreviations [F1],[F2],[F3],[F4] appear on the display. Test N° 2 [t2] It switches on the sea water pump for 5 minutes. The message [t.P] appears on the
display. Test N° 4 [t4] Test N° 3 [t3] It sets up the fan at medium speed (F2), the pump and the compressor for 5 minutes.
The message [t.C] appears on the display. How to set up the test function When the panel is offPress the S button + the On/Off button (for 3 seconds) > [PASS] > Press the S button
> press the
Arrow for boat Up or the Arrow Down button to display [123] > Press the S button
(Hidden parameters) > Press the Arrow Up or the Arrow Down button to select the
parameter [tSt] > Press the S button > Press the Arrow Up or the Arrow Down button
to select the desired test or sequence .
To move from one test to another interrupting the one in execution, use the Arrow Up
or the Arrow Down button.
To go out from the test function and to interrupt the test in execution, press the On/Off
button. Parameters ti.H & ti.L- timer Functioning time="ti.H" corresponds to the thousands"ti.L" corresponds to the unitsThe timer resolution is 1 hour. How to display the p arameter ti.H When the panel is off
Press the S button + the On/Off button (for 3 seconds) > [PASS] > Press the s button
> [0] > Press the Arrow up or the Arrow down button to display the number [123] >
Press the S button > [C10] > Press the Arrow Up or the Arrow Down to display the
parameter [ti.H] > Press the S button > It displays the thousands value > Press the S
button to go out How to display the p arameter [ti.L] When the panel is off
Press the S button + the On/Off button (for 3 seconds) > [PASS] > Press the S button
> Press the Arrow Up or the Arrow Down button to display [123] > Press the S button
> [C10] > Press the Arrow Up or the Arrow Down to display the parameter [ti.L] > Press
the S button > It displays the units value > Press the S button to go out
For example:
If ti.H=3
and ti.L=245
The running hours are 3245. Pag. 15 >