Catalogue Vega MKII
www.veco.net
print switch display
Page / 25
Manufacturer's
contact details
Where to buy
this product ?
Request
a Quote
Veco - 59804, 63944, 57654
/ 25
See other catalogues for Veco
Text version of the page
It switches on all the warning lights for boats and all the display segments. Test N° 5 [t5]

8 - HIDDEN PARAMETERS

T It switches on and off three times the valve/resistance relay for boats (once per second). Then it sets up the fan at medium speed (F2) and switches on again the valve/resistance relay for 5 minutes. During the test the message [t.H] appears on the display. est with a Comp act/S plit unit Test ALL[ALL] The test ALLsets up the tests sequence t1-t2-t3-t4-t5. Test N° 1 [t1] It sets up the fan and commutes the four speeds to a sequence (20 seconds for each one). The abbreviations [F1],[F2],[F3],[F4] appear on the display. Test N° 2 [t2] It switches on the sea water pump for 5 minutes. The message [t.P] appears on the display. Test N° 4 [t4] Test N° 3 [t3] It sets up the fan at medium speed (F2), the pump and the compressor for 5 minutes. The message [t.C] appears on the display. How to set up the test function When the panel is offPress the S button + the On/Off button (for 3 seconds) > [PASS] > Press the S button > press the Arrow for boat Up or the Arrow Down button to display [123] > Press the S button (Hidden parameters) > Press the Arrow Up or the Arrow Down button to select the parameter [tSt] > Press the S button > Press the Arrow Up or the Arrow Down button to select the desired test or sequence . To move from one test to another interrupting the one in execution, use the Arrow Up or the Arrow Down button. To go out from the test function and to interrupt the test in execution, press the On/Off button. Parameters ti.H & ti.L- timer Functioning time="ti.H" corresponds to the thousands"ti.L" corresponds to the unitsThe timer resolution is 1 hour. How to display the p arameter ti.H When the panel is off Press the S button + the On/Off button (for 3 seconds) > [PASS] > Press the s button > [0] > Press the Arrow up or the Arrow down button to display the number [123] > Press the S button > [C10] > Press the Arrow Up or the Arrow Down to display the parameter [ti.H] > Press the S button > It displays the thousands value > Press the S button to go out How to display the p arameter [ti.L] When the panel is off Press the S button + the On/Off button (for 3 seconds) > [PASS] > Press the S button > Press the Arrow Up or the Arrow Down button to display [123] > Press the S button > [C10] > Press the Arrow Up or the Arrow Down to display the parameter [ti.L] > Press the S button > It displays the units value > Press the S button to go out For example: If ti.H=3 and ti.L=245 The running hours are 3245. Pag. 15
NauticExpo's Virtual Library: PDF Catalogues | Documentation | Boating Brochures | Manuals | Marine directory | Specifications | Characteristics
Search Go
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8
page 9 p.9
page 10 p.10
page 11 p.11
page 12 p.12
page 13 p.13
page 14 p.14
page 15 p.15
page 16 p.16
page 17 p.17
page 18 p.18
page 19 p.19
page 20 p.20
page 21 p.21
page 22 p.22
page 23 p.23
page 24 p.24
page 25 p.25
pdf-page pdf ne En 2009-11-48-24