7 - ALARMS FOR BOATS / MESSAGES 7.1 HPAlarm7.2 Message [C.FL]
ONLYwhen the Vega MK II is connected to a Compact/Split unit.You can see a point on the right of the display. When the high pressure switch springs
shut for the third time, the abbreviation [HP] appears on the display and the system
stops.
You must switch off and on the panel (with the On/Off button or by the remote-control
device) to cancel the alarm signal and set up again the unit. The abbreviation [C.FL] suggests the user to clean the filter (2500 running hours). How to reset the message [C.FL] When the panel is on
Press the S button (for 3 seconds) > [SET] > Press the
Arrow for boat Down button to select
[r.ti] (reset timer) > Press the S button > Press the Arrow Up or the Arrow Down but-
ton to select [Yes] > Press the S button >
7.3 Message [nor]
In Dehumidify Mode, when the Vega MK II is connected to a Fan Coil unit.
The circuit water is above ) 25° C. >
7.4 Message [n.Pr]
The message [n.Pr] appears when the dip switch of the powerboard is not set out (see
Chapter 2: 2.2) or because of datas communication problems between the power-
board for boats and the Vega MK II panel and if the CHANGEOVER is not connected. >
7.5 Message [NA]
The message [nA] (not Available) appears on the display when the Vega MK II is con-nected to a Compact/Split unit of the CO type (Cool Only) and it is necessary to heat
the environment. Pag. 12 >