4- FUNCTIONING MODES (Mod) 4.1 Automatic Mode (A) - Default Mode
How to set up the In Automatic Mode the Vega MK II panel automatically selects the functioning mode(cool or heat) to reach and keep the "Set" temperature.
The Heat or Cool warning
lights for boats indicate the functioning mode.
If the panel controls a Fan Coil unit, the Heat and Cool warning lights blink when the
panel demand does NOTcorrespond to the temperature of the Fan Coil supply circuit.
When the function (A) is set up, the temperature is kept to the set up value +/- the dif-
ferential value (parameter C10). Press the (A) button. With the remote-control device Automatic Mode When the panel is on Press the s button (for 3 seconds) > [SET] > Press the
Arrow for boat Down button to select
Mode > Press the S button > Press the Arrow Up or the Arrow Down button to select
[A] > Press the S button Setting out p arameters Parameter C10 (Differential) (Default=1° C)
How to change the p arameter C10 When the panel is off Press the S button + the OFF button (for 3 seconds) > [PASS] > Press the S button
>[0] > Press the Arrow Up or the Arrow down button to display the number 123 > Press
the S button > [C10] > Press the S button > Press the Arrow Up or the arrow Down
button to obtain the differential desired value > Press the S button >
4.2 Fan Only Mode (FO)
.The Fan Only Mode sets up only the fan. How to set up the Fan Only Mode. When the panel is on Press the S button (for 3 seconds) > [SET] > Press the Arrow Down button to select
[Mod] > Press the S button < Press the arrow Up or the arrow down button to select
[FO] > Press the S button With the remote-control device Press once or more times the (M) button to select [FO] Pag. 7 >