| the run and stop operation and also for the "Cool-Heat" selection if the system has this function. 3.3 Stop from the main box: Turn the "Control" or "Mode" switch to "0". 3.4 Stop from the remote panel Turn the remote panel switch to "0". 3.5 Pumps Pumps start as the main switch is turned into Cool or Heat mode or when the "Control" switch is turned to "1". 3.6 Spare pump control If there is a "duty" pump and a "spare" pump, the electrical box is equipped with a dedicated change over switch for each set of two pumps. This switch controls the use of the duty pump (position 1) or the spare pump (position 2). Before switching from position 1 to position 2, you must make the necessary changes in the sea and/or fresh water circuit, closing and opening valves in order to connect the chosen pump in the circuit. 3.7 Alarm reset In order to reset the compressor alarm it is necessary to: a) check the reasons of the alarm and restore the normal functioning conditions b) push the yellow "RESET" button for 5 seconds . This operation puts off the alrm lights for boats and will restore the starting procedure, and the compressors will restart automatically within 6 minutes. The temperature in each cabin is controlled by a room thermostat, which controls the fan motor. The panel (Fan Coil) change over switch must be set In "Sun" position and the thermostat must be set to medium (horizontal setting). The fan speed control can run the fan on three different speeds. The minimum speed is in the centre of the fan control switch. |