AIR-CONDITIONERS
COMPACT and SPLIT QUATTRO models >
3 INSTALLATIONOFTHECOMPONENTS 3.5 - FASTENING
The fastening must be executed as indicated. NEOPRENE >
Figure 1.8
Dis 2.8
Figure 2.8 3.6 - CONDENSATIONOUTLET
The air-conditioning determines the separation ofthe condensation water due to the humidity of the
conditioned air. This condensation must be dis-
charged in the bilge or in a special tank and then by
means of a self-priming pump in the sea. The direct bulkwark outlet is not the best solution: in
fact, it can suck up unpleasant smells due to the
exhaust emissions of its own or of other engines. Make reference to the safety regulations of the
different countries The water condensation
outlet pipe must be
linked to the rubber-
holders of 19 mm on the
condensation collection
basin. >
Each unit is endowed with two out-
lets, as you can see in the picture
above. If the condensation discharge pipe for exigencies
of installation must be long, it is better to use the
special “L” connection. You must avoid such an
installation as you can see in the picture 1.8
because the condensation water can stop and flow
back to the collection basin because of the
boat suppliers
rocking. page 8 >