AIR-CONDITIONERS

COMPACT and SPLIT QUATTRO models
3 INSTALLATIONOFTHECOMPONENTS

3.14- MECHANICALCONTROLPANEL

By means of the control panel for boat, you can set and control the following functions:
A.-Switching on and offSUMMERAIR-CONDITIONING : push the “COOL” but-ton with the ice star.WINTERHEATING : push the “HEAT” button with the orange sun. To switch off, put the switch in the central position. B.- Setting-regulation of the temperature by means of the thermostat (TEMP). The thermostat has got a 3 m capillary with a bulb. The bulb must perceive the sucked up air (it must not come into contact with the exchanger for boat tongues; it is in fact the battery where the refrigerant spreads: the tongues cool down, so that if the bulb comes into contact with them, it will perceive a temperature value that is lower than the ambient temperature). C.- Regulation of the fan speed: by means of the button with the fan it is possible to regulate the four fan speeds. Push the button to select the fan speed: upwards arrow for boat means speed increase and downwards arrow means speed decrease. Switching on the fan for the first time, it will run in MED speed. Then it will run according to the last selected speed. 2.11.A- PLACING You must choose the correct position to connect the panel to the marine board by means of a 3 m cable (includ- ed) and to install the thermostat bulb on the unit exchanger. If necessary, you can install the bulb not directly on the exchanger but in the room, choosing the right position to control the temperature. To fas- ten the bulb on the wall, you can use the suitable plaque.2.11.B.- INTERCHANGEABLEPLAQUEThe standard plaque (included) is black.2.11.C - FASTENINGThe panel has been designed for a casing fasten- ing. You must drill into it as indicated on the right. IMPORTANTNOTE:
In the panel there is only low voltage. After having installed it,the back must not be accessible. An optional protection cover (code: M69330) is avail-able. If the panel back is accessible because it may suffer damages.

3.15- DIGITALCONTROLPANEL VEGAMKII (optional)

For the technical specifications and for the installation direc- tions, make reference to the manual VEGAMKII
(code:A52000). page 14

www.climma.it

NauticExpo's Virtual Library: PDF Catalogues | Documentation | Boating Brochures | Manuals | Marine directory | Specifications | Characteristics
Search Go
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8
page 9 p.9
page 10 p.10
page 11 p.11
page 12 p.12
page 13 p.13
page 14 p.14
page 15 p.15
page 16 p.16
page 17 p.17
page 18 p.18
page 19 p.19
page 20 p.20
page 21 p.21
page 22 p.22
page 23 p.23
page 24 p.24
page 25 p.25
page 26 p.26
page 27 p.27
page 28 p.28
page 29 p.29
page 30 p.30
page 31 p.31
page 32 p.32
page 33 p.33
pdf-page pdf ne En 2009-11-48-24