Text version of the page
AIR-CONDITIONERS
COMPACT and SPLIT QUATTRO models
3 INSTALLATIONOFTHECOMPONENTS
AIR DISTRIBUTION LAYOUT EXEMPLE DE DISTRIBUTION D’AIR ESEMPI DI DISTRIBUZIONE ARIA
ONE OUTLET - UNE SORTIE SEULEMENT - UNA SOLA USCITA
A5 A5 12 12 L1 L1 A5 Btu/h 2 L1 A 4000-5000 100 3 300x112 6000-9000 100 3 300x112 12 10000-13000 125 3 400x112 L1 14000-17000 150 3 400x172 >
TWO OUTLET - DEUX SORTIES - DUE USCITE
A A B56 B56 1234 12344 L1 L2 L1 L2 Btu/h 2 L1 A 4 L2 B 4000-5000 100 3 200x76 3 75 200x76 6000-9000 100 3 300x112 3 75 200x76 10000-13000 125 3 400x76 3 75 200x76 14000-17000 150 3 400x112 3 100 300x112 >
1 = Air-conditioning unit - Unitè de climatisation - Unità condizionatore 2 = Main air duct - Gaine d’air principal - Condotta d’aria principale 3 = Air splitter plenum - Plenum distribution air - Plenum di divisione aria 4 = Secondary air duct - Gaine d’aire secondaire - Condotta aria secondaria 5 = Air plenum - Plenum grille - Plenum per griglia 6 = Air plenum - Plenum grille - Plenum per griglia A = Main air delivery grill - Grille distribution principale - Griglia di mandata aria principale B = Secondary air delivery grill - Grille distribution secondaire - Griglia di mandata aria secondaria
DUCT SPECIFICATIONS - SPECIFICATION DU GAINE - SPECIFICHE DELLA CONDOTTA
1 = SUGGESTED - CONSEILLE - SUGGERITO 2 = ACCEPTED - ACCEPTE - ACCETTATO 3 = WRONG - DECONSEILLE - SCONSIGLIATO
R min=1.5 D 1 2 3 R1-R2 min= 2D >
C331 05/96
page 12