Catalogue Aladain Prime and Tec
www.uwatec.com
print switch display
Page / 48
Make a request   
Uwatec - 163827
/ 48
See other catalogues for Uwatec
Text version of the page

Safety considerations I

•Avoid repeated ascents and descents (yo yo diving).•Avoid repeated heavy workload while at depth. •Plan the dives to be shorter if they are made in cold water. •After finishing the decompression or at the end of a no-stop dive, the final stage of the ascent shouldbe as slow as possible. •You MUST be familiar with all signs and symptoms of decompression sickness before using Aladin
® PRIME and Aladin
® TEC ! Seek IMMEDIATE treatment for decompression sickness should any of thesesigns or symptoms occur after a dive! There is a direct correlation between the effectiveness of treat- ment and the delay between the onset of symptoms and the treatment for decompression sickness.•Only dive with Nitrox after you have been thoroughly instructed by a recognised institution.
English Repetitive dives •Do not start your next dive before your CNS O
2 % status has dropped below 40%.•Diving with Nitrox: Make sure your surface interval is long enough (just like diving with compressedair). Plan for a minimum surface interval of two hours. Oxygen, too, needs sufficient time to leave the body.•Match gas mixture to the intended dive. •Do not attempt a repetitive dive if the microbubble warning is visible on the display. •Plan a day without diving once a week. •If you have to change computers, wait at least 48 hours before carrying out your next dive. • Diving after a reset of the remaining saturation (reset, see page 41, or battery replacement, see page 45) may lead you into
NO potentially hazardous situations which could result in death or seriousinjury. After a reset of the remaining saturation do not dive for at least 48 hours. Altitude and diving •Do not dive at altitudes higher than 4000m (13000 feet). •After a dive do not rise to altitudes that Aladin
® PRIME or Aladin
® TEC prohibit via the flashing altitude range number (see page 27). Flying after diving •After diving, wait at least 24 hours prior to flying. Aladin
® PRIME and Aladin
® TEC dive instruments are a personal protective equipment in compliance withthe essential safety requirements of the European Union directive 89/686/EEC. RINA SpA, Via Corsica 12,I-16128 Genoa, notified body no. 0474, have certified the conformity with the European Standard EN 13319:2000.EN13319:2000 Diving accessories - Depth gauges and combined depth and time measuring devices -Functional and safety requirements, test methods. Any information on decompression obligation display- ed by equipment covered by this standard is explicitly excluded from its scope.
I UWATEC ® Aladin ® dive computers

3

NauticExpo's Virtual Library: PDF Catalogues | Documentation | Boating Brochures | Manuals | Marine directory | Specifications | Characteristics
Search Go
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8
page 9 p.9
page 10 p.10
page 11 p.11
page 12 p.12
page 13 p.13
page 14 p.14
page 15 p.15
page 16 p.16
page 17 p.17
page 18 p.18
page 19 p.19
page 20 p.20
page 21 p.21
page 22 p.22
page 23 p.23
page 24 p.24
page 25 p.25
page 26 p.26
page 27 p.27
page 28 p.28
page 29 p.29
page 30 p.30
page 31 p.31
page 32 p.32
page 33 p.33
page 34 p.34
page 35 p.35
page 36 p.36
page 37 p.37
page 38 p.38
page 39 p.39
page 40 p.40
page 41 p.41
page 42 p.42
page 43 p.43
page 44 p.44
page 45 p.45
page 46 p.46
page 47 p.47
page 48 p.48
pdf-page pdf ne En 2008-10-41-07