Text version of the page
Technical Info
Technical Data
Sizes:
Length (mm) 1200Width (mm) 600
Thickness (mm) 6,8,10,12 >
Tolerances:
Thickness + Length / Width
+ 1mm 3mm An extensive fire testing program has been
successfully carried out in our laboratory on
the following structures using PROMAGUARD: >
• Deckhead and bulkhead Steel A60 >
• Deckhead and bulkhead Aluminum A30 - A60 >
• Deckhead and bulkhead GRP B15 - A30 >
Classification TemperatureNominal density (core)Glass cloth weightLinear Shrinkage at referring temperatureSpecific heatThermal conductivity at meantemperature ofTypical composition (core)Organic content Microporous coreGlass Cloth
200°C400°C
600°C
800°CSiCSiO2CaO °CKg / m 1000650240 +/-10%210<2 @ 900 °C1.050.022 - 0.0250.028 - 0.033
0.035 - 0.039