video corpo

TYPE CLIMASTER ZCR
30Pages

{{requestButtons}}

Catalog excerpts

TYPE CLIMASTER ZCR - 1

MU 13662 1008 Hi-Pres® Air Handling Unit TYPE CLIMASTER ZCR HI-PRES MARINE & OFFSHORE Product specications

Open the catalog to page 1
TYPE CLIMASTER ZCR - 2

HI-PRES MARINE & OFFSHORE 3.1 Air Handling Units Products 3.1 Air Handling Units Contents Introduction. . . . . . . . . . . . . . . . . . . . . 2 Air handling units type ZCR . . . . . . . . . . . . . . . 2 Air Handling Unit type ZCR . . . . . . . . 3 Scope. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Classifications . . . . . . . . . . . . . . . . . . . . . . . . . 3 Design . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Surface Treatment . . . . . . . . . . . . . . . . . . . . . . 4 Acoustic and Thermal Insulation . . . . . . . . . . . 4 Air Tightness ....

Open the catalog to page 2
TYPE CLIMASTER ZCR - 3

HI-PRES MARINE & OFFSHORE 3.1 Air Handling Units Products Introduction To achieve the necessary air treatment required for the systems described in the section Hi-Pres Air Conditioning Systems, Novenco has developed three series of air handling units. Marine air handling units type ZCR is a unit type designed specially for marine installations for air conditioning. All units are flexible and each make up compact systems for combination of air handling components into complete units. Thus, a large number of different versions are available to satisfy any specific air conditioning...

Open the catalog to page 3
TYPE CLIMASTER ZCR - 4

HI-PRES MARINE & OFFSHORE 3.1 Air Handling Units Products Air Handling Unit type ZCR ZCR Air Handling Unit The Marine Air Handling unit type ZCR is spe- Scope cially designed for marine installations for air 10 sizes with airflows from 0.3 to 9 m3/s. Max. conditioning. Air Handling Unit type ZCR is com- negative pressure 2000 Pa and max. positive pres- pact and flexible for a large combination of air sure 1500 Pa in casing. Discharge section, how- handling components into complete units. ever, 2500 Pa. The unit is developed in close cooperation with major customers, able to meet the most...

Open the catalog to page 4
TYPE CLIMASTER ZCR - 5

HI-PRES MARINE & OFFSHORE 3.1 Air Handling Units Products Design Air Tightness The sections are constructed from a framework The Air Handling Units type ZCR meet the re- covered with panels. The panels are 50 mm thick quirements for class A according to CEN 1886, and consist of a double skinned steel sheet with which corresponds to a leakage of 4.75 m3/h per intermediate mineral wool. m2 surface of the air handling unit, at 400 Pa posi- The frame is assembled by means of insertion tive pressure. joints and has soft rounded edges. The side panels are screwed onto the frame and are easy to...

Open the catalog to page 5
TYPE CLIMASTER ZCR - 7

HI-PRES MARINE & OFFSHORE Position designations The position designations of the air handling units generally refer to the direction of airflow through the unit seen from the access side. Pos. R: Airflow direction from left to right. Pos. L: Airflow direction from right to left. As far as high air handling units (combined sup- ply and exhaust) are concerned, the position des- ignation refers to the direction of the supply air. Centrifugal fans for high pressure only for motor size 160M only for motor size 200L Owing to continued product development Novenco reserves the right to introduce...

Open the catalog to page 7
TYPE CLIMASTER ZCR - 8

HI-PRES MARINE & OFFSHORE 3.1 Air Handling Units Products Dimension sketch Fan positions: Outlet Pos. A End Centrifugal fan Pos. B Outlet Top Pos. C Centrifugal fan Pos. E Service Spaces The required space in front of the unit depends on Service Spaces [mm] the width of the serviced components. Filters re- AHU type ZCR Minimum Maximum quire little space while fans and rotors require the 9/4 700 1030 9/6 700 1030 9/8 most. 700 1030 The worst case for required service space is given 13/6 700 1420 by the width of the unit plus 50 mm. Add to this 13/8 700 1420 13/12 700 1420 18/8 700 1650 the...

Open the catalog to page 8
TYPE CLIMASTER ZCR - 9

HI-PRES MARINE & OFFSHORE Sections - optional The components listed below can, in principle, be freely combined and mounted in casings to form complete sections. Overall Lengths A section consists of functions shown in the table The overall length of a section is calculated as the sum of the individual functions lengths + 37 mm. Every time you join individual functions to form a section the additional 37 mm is needed for con- Min. length of a section is 240 mm. So the total minimum length of a section is 240 + 37 mm = 277 Max. length of a section casing is 3120 mm. Total maximum length of a...

Open the catalog to page 9
TYPE CLIMASTER ZCR - 10

HI-PRES MARINE & OFFSHORE Mixing damper Pocket filter Pocket filter/ short fine filter Pocket filter, fine filter Heating coil, Owing to continued product development Novenco reserves the right to introduce alterations without prior notice Air Handling Unit type ZCR

Open the catalog to page 10
TYPE CLIMASTER ZCR - 12

HI-PRES MARINE & OFFSHORE 3.1 Air Handling Units Products *) Section length for enthalpy exchanger. Owing to continued product development Novenco reserves the right to introduce alterations without prior notice Air Handling Unit type ZCR

Open the catalog to page 12
TYPE CLIMASTER ZCR - 13

HI-PRES MARINE & OFFSHORE 3.1 Air Handling Units Products Sections – purpose built The AH sections are for Spiroduct connections. The sections listed below cannot be extended to The AL sections are for connection to square house additional functions/components. The sec- ducts. tions will be designed from case to case, in order The heights normally vary between the min. and to obtain the optimum solution, concerning the max. heights in steps of 200 mm. lengths and the heights. The lengths vary between the min. and max. The widths of the sections are the same as the lengths in steps of 80 mm....

Open the catalog to page 13
TYPE CLIMASTER ZCR - 14

HI-PRES MARINE & OFFSHORE The sketches on these pages show a few examples of our medium size arrangements for different Single pipe/Single pipe Re-heat types of installations and operating conditions but many other possibilities are available. The dimensions given are for guidance only. Mixing, filter, heating, humidifying, cooling, fan and spiroduct discharge Mixing, filter, heating, humidifying, cooling, fan and spiroduct discharge Inlet, filter, enthalpy exchanger, heating, humidifying, cooling, fan and spiroduct discharge Owing to continued product development Novenco reserves the right...

Open the catalog to page 14

All Novenco catalogs and brochures

  1. NovPac-R

    2 Pages

  2. ZPR

    2 Pages

  3. Super Speed

    2 Pages

  4. workboats

    4 Pages

  5. navy system

    4 Pages

  6. FLEXAIR

    8 Pages

  7. ZerAx axial

    20 Pages

  8. ZCR

    32 Pages

  9. MICROVENT

    8 Pages

  10. CND and CNF

    24 Pages

  11. MICRO VENT

    8 Pages

  12. NOVPAC R

    2 Pages

  13. CNA-CNB

    20 Pages

Archived catalogs

  1. ACN

    28 Pages

  2. CAL

    40 Pages

  3. VMA-VMB

    24 Pages

  4. SJD

    12 Pages

  5. ZCP

    36 Pages