Catalog excerpts
Novenco Centrifugal Fans CAL May 2003
Open the catalog to page 1Product Facts A robustly built centrifugal fan of the medium pressure type for For process air in composting plants and other installations in aggressive installations with high physical Working Range The standard range comprises 24 installation sizes in the belt-driven version (impeller diameters from installation sizes in the directly coupled version (impeller diameters Air flow rates from 0.3 m3/s to Welded housing, impeller and bearing bracket. In a belt-driven or directly coupled two-part steel bearing housings with spherical roller/ball bearings. Housing: Heavy sheet steel, steel 37-2...
Open the catalog to page 2Novenco Centrifugal Fans CAL Regulation of Air Flow Rate 37
Open the catalog to page 3CAL is a robustly built compact pressure type, primarily designed for process air in composting plants and other installations in aggressive environments. It is also well suited to a wide range of industrial purposes with high physical load and long life requirements. sizes in a belt-driven version (impeller diameters from 315 mm to directly coupled version (impeller Air flow rates from 0.3 m3/s to 21 The fan consists of a robustly welded housing with angle stiffeners, an impeller, a combined motor and bearing bracket and a support bracket on the inlet side. The stiffeners and brackets are...
Open the catalog to page 4General Diagrams For each fan size, a working range is plotted in which the efficiency is greater than 75%, with an indication Continuous product development at Novenco may result In changes being introduced without prior notice.
Open the catalog to page 5Duct boss Outlet flange Dependent on the motor size. Weight excl. motor NB: On the mating flange, A and B dimensions are table value + 5 mm X and Y dimensions are table value - 5 mm r and q dimensions are table value - 2.5 mm Continuous product development at Novenco may result in changes being introduced without prior notice.
Open the catalog to page 6Dimensioned Drawings, CAL - 100%/Direct Motor size 250-280 Duct boss Dimensions in mm Drain plug 1½’ RG 100% A B Bu C1 D E E1 F F1 CAL-1120 CAL-1250 1120 1250 784 875 796 887 190 213 900 1000 996 1100 1796 1887 1310 1463 845 942 100% G G1 L Weight 2) kg CAL-1120 CAL-1250 1048 1169 69 69 1047 1188 r n x 100 762 850 H J Pos. 0 Pos. 90 Pos. 180 Pos. 270 250-280 1120 1250 900 1000 800 900 1400 1600 850 8503) Outlet flange r q p r n CAL-1120 70 11 102 7 CAL-1250 85 12 97.5 8 T X S Y u 1180 1240 844 904 40 1310 1370 935 995 44 q 100% T X A NB: On the mating flange, A and B dimensions are table...
Open the catalog to page 7Dimensioneel Drawings, CAL - 100% I Belt-driven Motor size 112-225 Duct boss depending on the anti-vibration mountings. 2) Dependent on the motor size. 3) Weight excl. motor and belt drive Outlet flange A and B dimensions are table value + 5 mm X and Y dimensions are table value - 5 mm r and q dimensions are table value - 2.5 mm Continuous product development at Novenco may result in changes being introduced without prior notice.
Open the catalog to page 8Dimensioneel Drawings, CAL - 100% I Belt-driven Duct boss depending on the anti-vibration mountings. 2) Weight excl. motor Outlet flange NB: On the mating flange, A and B dimensions are table value + 5 mm X and Y dimensions are table value - 5 mm r and q dimensions are table value - 2.5 mm Position of motor in accordance with EUROVENT Continuous product development at Novenco may result in changes being introduced without prior notice.
Open the catalog to page 9Duct boss depending on the anti-vibration mountings. 2) Dependent on the motor size. 3) Weight excl. motor Outlet flange NB: On the mating flange, A and B dimensions are table value + 5 mm X and Y dimensions are table value - 5 mm r and q dimensions are table value - 2.5 mm Position of motor in accordance with EUROVENT Continuous product development at Novenco may result in changes being introduced without prior notice.
Open the catalog to page 10Duct boss depending on the anti-vibration mountings. 2) Weight excl. motor Outlet flange NB: On the mating flange, A and B dimensions are table value + 5 mm X and Y dimensions are table value - 5 mm r and q dimensions are table value - 2.5 mm Position of motor in accordance with EUROVENT Continuous product development at Novenco may result in changes being introduced without prior notice.
Open the catalog to page 11Dimensioneel Drawings, CAL - 85% I Belt-driven Duct boss depending on the anti-vibration mountings. 2) Dependent on the motor size. 3) Weight excl. motor and belt drive Outlet flange NB: On the mating flange, A and B dimensions are table value + 5 mm X and Y dimensions are table value - 5 mm r and q dimensions are table value - 2.5 mm Position of motor in accordance with EUROVENT Continuous product development at Novenco may result in changes being introduced without prior notice.
Open the catalog to page 12Dimensioneel Drawings, CAL - 85%/Belt-driven Motor size 250-28O Duct boss Drain plug 1 Vi RG Dimensions in mm depending on the anti-vibration mountings. 2) Weight excl. motor and belt drive Outlet flange NB: On the mating flange, A and B dimensions are table value + 5 mm X and Y dimensions are table value - 5 mm r and q dimensions are table value - 2.5 mm Position of motor in accordance with EUROVENT Continuous product development at Novenco may result in changes being introduced without prior notice.
Open the catalog to page 13depending on the anti-vibration mountings. 2) Weight excl. motor. Outlet flange NB: On the mating flange, A and B dimensions are table value + 5 mm X and Y dimensions are table value - 5 mm r and q dimensions are table value - 2.5 mm Position of motor in accordance with EUROVENT Continuous product development at Novenco may result in changes being introduced without prior notice.
Open the catalog to page 14Duct boss Outlet flange depending on the anti-vibration mountings. 2) Dependent on the motor size. 3) Weight excl. motor NB: On the mating flange, A and B dimensions are table value + 5 mm X and Y dimensions are table value - 5 mm r and q dimensions are table value - 2.5 mm Continuous product development at Novenco may result In changes being introduced without prior notice.
Open the catalog to page 15Dimensioneel Drawings, CAL - 70% I Direct Duct boss Outlet flange NB: On the mating flange, A and B dimensions are table value + 5 mm X and Y dimensions are table value - 5 mm r and q dimensions are table value - 2.5 mm depending on the anti-vibration mountings. 2) Weight excl. motor Continuous product development at Novenco may result in changes being introduced without prior notice.
Open the catalog to page 16All Novenco catalogs and brochures
-
NovPac-R
2 Pages
-
ZPR
2 Pages
-
Super Speed
2 Pages
-
workboats
4 Pages
-
navy system
4 Pages
-
FLEXAIR
8 Pages
-
ZerAx axial
20 Pages
-
ZCR
32 Pages
-
TYPE CLIMASTER ZCR
30 Pages
-
MICROVENT
8 Pages
-
CND and CNF
24 Pages
-
MICRO VENT
8 Pages
-
NOVPAC R
2 Pages
-
CNA-CNB
20 Pages
Archived catalogs
-
Navy System 1
4 Pages
-
ACN
28 Pages
-
VMA-VMB
24 Pages
-
SJD
12 Pages
-
ZCP
36 Pages