Air cooler drain water is collected into a collecting tank*. Two monopumps discharges air
cooler drain water through the Whitebox CBD and overboard if the water contains less
than 15 ppm oil . If the water contains more than 15 ppm oil it will be diverted to the bilge
holding tank and shall be treated as regular bilge water. A tank radar controls the tank
level in the AC drain tank by supplying start and stop signal to the pumps. The process is
operated from a control box and is fully automatic.
* If a collecting tank is not present it can be included in the Marinfloc scope of supply. A 2
m³ tank will cover most needs.
For safe overboard discharge of main engine Air Cooler Drain Water
System description:
Marinfloc AB, Industrivägen 10 , 472 95 Varekil, Sweden
Phone: +46 (0)304 606300
Fax: +46 (0)304 10051
E-mail: marinfloc@marinfloc.com
CBD Unit
Whitebox ”Lite” 2(2) Rev 1 20080712
Control Cabinet
Pumps
White Box CBD
To Overboard
MEPC 107 (49)
Recirculating Facility
Return Line
Bilge Holding Tank
AC Drain Tank
AC Drain
Radar
|
|