BILGE, DECKWASH AND REFUELLING
CE marked according to following standards:
Pressure and Capacity Data
(based on water at 20°C/68°F)
F2P10-19, F3B-19, F4B-19, F4B-11
EN50082-1: 1992/Generic EMS Standard
EN55014: 1993/Radio disturbance
IEC801-2: 1984/Electrostatic Discharge
IEC801-3: 1984/Radiated Immunity Test
ISO8846: Small Craft - Electrical devices - Protection against
ignition of surrounding flammable gases ISO8849: Small Craft - Electrically operated bilge pumps ISO10133: Small Craft - Electrical systems - Extra-low voltage d.c.
installations
F5B-19 12/24 V
EN55014: 1993/Radio disturbance
With their high level of flexibility, these pumps are ideally suited for use in boats as bilge and deckwash pumps, fresh water pumps, refuelling pumps for oil and diesel. These pumps may be combined with a vacuum switch for automatic operation.
Capacities vary from max 14 L/min to 55 L7min, allowing the proper matching of the pump to the application. All motors are heavy duty to provide long service life even under heavy use. Available in 12 or 24 volts.
Oil Change
These DC driven flexible impeller pumps are deally suited for drain and refueling of both engine oil and diesel.
Deckwash Pumping
DC driven flexible impeller pumps for deckwash. Heavy duty electrical self-priming deckwash pumps with long life motor which can run continuously under certain conditions. Flexible impeller pumps must not be run dry.
Bilge Pumping
Bilge pumps with excellent suction and pressure ability. Solid particles and debris can be handle without damaging the pump. Should be installed in a dry, well ventilated position above, but as close to the liquid as possible. As the pumps must not be run dry, it is recommended to combine it with Johnson Pump vacuum switch that cuts off the current to the pump when the bilge is dry. For automatic/manual bilge pumping the pump can be combined with Johnson Pump bilge control panel and automatic switch. Must not be run dry.
| F2P10-19 | Ampere draw |
| Bar | z | kPa | psi | l/min | USGPM | 12V | 24V 1 |
| Cont. Duty I |
| 0 | | 0 | 0 | 15.0 | 4.0 | 5.6 | 4.0 |
| 0.1 | | 10 | 1.45 | 14.5 | 3.8 | 5.7 | 4.0 |
| 0.2 | | 20 | 2.90 | 14.0 | 3.7 | 5.8 | 4.1 |
| 0.3 | | 30 | 4.35 | 13.5 | 3.6 | 5.9 | 4.1 |
| 0.6 | | 60 | 8.7 | 11.0 | 2.9 | 6.1 | 4.2 |
| Intermittent duty | |
| 0.75 | 75 | 10.8 | 9.6 | 2.5 | 6.5 | 4.3 |
| 0.9 | 90 | 13.0 | 7.0 | 1.8 | 6.5 | 4.8 |
| Fuse required | 15 A | 8 A |
| | |
| F3B-19 | Ampere draw I |
| Bar | z | kPa | | l/min | USGPM | 12V | 24V 1 |
| Cont. Duty | |
| 0 | | 0 | 0 | 21.0 | 5.5 | 8.4 | 4.0 |
| 0.1 | | 10 | 1.45 | 20.5 | 5.4 | 8.5 | 4.0 |
| 0.2 | | 20 | 2.9 | 20.0 | 5.3 | 8.6 | 4.1 |
| 0.3 | | 30 | 4.35 | 19.5 | 5.2 | 8.8 | 4.1 |
| 0.6 | | 60 | 8.7 | 17.8 | 4.7 | 9.0 | 4.2 |
| Intermittent drift | |
| 0.9 | 90 | 13.0 | 15.6 | 4.1 | 9.6 | 4.3 |
| 1.2 | 120 | 17.4 | 12 | 3.2 | 10.3 | 4.8 |
| Fuse required | 15 A | 8 A |
| |
| F38B-19 | Ampere draw I |
| Bar | z | kPa | | l/min | USGPM | 12V | 24V 1 |
| Cont. Duty I |
| 0 | | 0 | 0 | 35.0 | 9.2 | 10.9 | 5.0 |
| 0.1 | | 10 | 1.45 | 33.8 | 8.9 | 11.0 | 5.1 |
| 0.2 | | 20 | 2.9 | 32.2 | 8.5 | 11.0 | 5.1 |
| 0.3 | | 30 | 4.35 | 31.0 | 8.2 | 11.1 | 5.2 |
| 0.6 | | 60 | 8.7 | 25.5 | 6.7 | 11.9 | 5.4 |
| Intermittent duty | |
| 0.9 | 90 | 13.0 | 15.3 | 4.0 | 13.6 | 6.0 |
| 1.2 | 120 | 17.4 | 2.0 | 0.5 | 15.8 | 7.1 |
| Fuse required | 20 A | 10 A |
| | |
| F4B-19 | Ampere draw I |
| Bar | | kPa | | l/min | USGPM | 12V | 24V 1 |
| Cont. duty I |
| 0 | | 0 | 0 | 48.0 | 12.7 | 12.2 | 6.5 |
| 0.1 | | 10 | 1.45 | 45.0 | 11.9 | 12.3 | 6.7 |
| 0.2 | | 20 | 2.9 | 44.5 | 11.7 | 12.2 | 6.8 |
| 0.3 | | 30 | 4.35 | 41.0 | 10.8 | 13.1 | 7.1 |
| 0.6 | | 60 | 8.7 | 34.0 | 9.0 | 14.9 | 7.5 |
| Intermittent duty | |
| 0.9 | 90 | 13.0 | 25.0 | 6.6 | 16.5 | 7.8 |
| 1.2 | 120 | 17.4 | 11.0 | 2.9 | 18.3 | 8.8 |
| Fuse required | 15 A | 8 A |
| F5B-19 | Ampere draw |
| Bar | kPa | psi | l/min | USGPM | 12V | 24V |
| 0 | 0 | 0 | 55.0 | 14.5 | 23.2 | 11.9 |
| 0.3 | 30 | 1.45 | 49.4 | 13.1 | 24.2 | 12.8 |
| 0.6 | 60 | 8.7 | 39.9 | 10.5 | 25.1 | 13.3 |
| 0.9 | 90 | 13.0 | 30.1 | 8.0 | 26.2 | 14.0 |
| 1.2 | 120 | 17.4 | 19.3 | 5.1 | 28.0 | 14.7 |
| 1.5 | 150 | 21.76 | 9.3 | 2.4 | 29.8 | 15.3 |
| Fuse required | | | | 50.0 A | 25.0 A |
| Recommended wire size | | | 16 mm2 | 6 mm2 |