FDO - 6 Pages

  1. P. 1

  2. P. 2

  3. P. 3

  4. P. 4

  5. P. 5

  6. P. 6

Catalogue excerpts

FDO in picture with flanges (available as an option) Halton FDO fire dampers are type-approved class A0(A60) fire dampers for use in marine and offshore ventilation systems. The FDO can be installed in circular ducts. All fire dampers have a fusible link and they prevent the spread of fire within the ventilation ductwork. When the blade is in the open position, the device does not cause significant pressure loss, noise or flow disturbance. Fire dampers are set from outside and can be installed in any position. An open-closed indicator is visible on the outside of the damper. • Type-approved by most recognized classification societies, class A0 - A60 fire damper when suitably insulated • Availabe as ATEX approved • Fixed frame of painted, galvanized or stainless steel. Blades stainless or galvanized steel. Flanges available as an option. • Blade contains seals (effective up to 270 °C) • Nominal fuse release temperature 50 °C, 74 °C or 100 °C. Other temperatures available. • Very low leakage • Automatic electrical, pneumatic or spring operation system available • Maximum duct pressure for damper construction 5000 Pa and maximum air velocity 15 m/s halton MARINE

 Open the catalogue to page 1

FDO DIMENSIONS AND MATERIAL THICKNESS Ø160 can be manufactured with 1 mm division. Flanges FDO fire dampers meet international standards for and drilling available as an option and according to ISO circular ducts (Ø100-500 mm). Sizes Ø100 and Ø125 15138 standards. Special flanges and drilling available on are not available of stainless steel. Sizes starting from request. Frame material thickness according to SOLAS. GENERAL FDO DRAWING (without flanges) FDO DRAWING (with flanges) T Damper Blade

 Open the catalogue to page 2

Damper size Inside dimensions Outside dimensions Material thickness Housing Lenght Elodrive CSQP /Schischek FDO Dimensions with flanges (as an option) M08Y2016/Halton Marine reserves the right to alter products without notice. WEIGHTS OF STANDARD HALTON MARINE FDO DAMPERS (KG) without an actuator FDO weight without flanges FDO weight with flanges Weights stated above do not include flanges or any actuator. Examples of actuator weights: FDO-EL CSQP +3,5 kg, BF230 +3,2 kg, BLF230 +1,7 kg, ExMax or RedMax or InMax +3,5 kg, FDO-PNR AT100 (AISI) +6,2 kg, AT50 (AISI) +3 kg, FDO-SP +1 kg. tlalton MARINE

 Open the catalogue to page 3

OPERATION PRINCIPLE Halton FDO is available with following actuators: In the event of a temperature rise in ductwork: • FDO-EL: Electrical spring return motor; standard • FDO-EL: fusible link releases and cuts off operating actuators being 24 V or 230 V or 120 V. The motor voltage to the spring return motor, allowing the contains built-in open-closed limit switches. Separate spring to close the damper blades. The fire damper junction box included in the EL-model. A wide range opens automatically when the fuse has been of eex-proof actuators available, including a one changed and the operating...

 Open the catalogue to page 4

DAMPER OPEN FUSIBLE LINK WHEN DAMPER IS NOT ENERGIZED CONTACTS S1-S2, S4-S6 ARE CLOSED FDO-PNR PNEUMATIC DIAGRAM 1. SPRING RETURN VALVE SPRING RETURN ACTUATOR 2. QUICK EXHAUST VALVE 3. SILENCER 4. FUSIBLE LINK VALVE 5. OPTION: SOLENOID VALVE SPEED CONTROLLER 6. MALE CONNECTOR 7. DOUBLE NIPPLE 8. PLASTIC TUBE. OPTION: STAINLESS STEEL 9. OPTION: OPEN / CLOSED SWITCHES 10. OPTION: MANUAL VALVE OPTION: MANUAL VALVE 3 PORT/2 WAY OPTION: SOLENOID VALVE 3 PORT/2 WAY PNEU. INLET (5 - 8 BAR) FOR A PLASTIC TUBE Ø6 MM CLOSED AND OPENED INFORMATION OUT FUSIBLE LINK VALVE 3 PORT/2 WAY QUICK EXHAUST VALVES OPTION:...