HMR Dual Duct Cabin Unitfor Passenger And Crew CabinsM08Y2006/Halton Marine reserves the right to alter products without notice. 1 V The Halton HMR is an automatic dual duct cabin unit. • Airflow measurements The airflow is continuously measured from the warm • MED approved, B-0/B-15 air spigot, as well as inside the box for total air volume. • Inputs to connect balcony door or other external Acting on these measurements, the volume flow rate devices available as an option is changed if required and is kept constant although the • Master/slave functionality: several slave cabin units cold and warm air-mixing ratio or duct pressure changes. can be connected to one master cabin unit. The total HMR adapts to variations in ductwork pressure from sum of IC cable (interconnection cable) length from 200Pa up to 1000 Pa and maintains individual conditions CP unit (Control panel) to last slave cabin unit can be in each cabin. up to 30 meters. • All parameters can be preset at the factory or set onsite during commissioning by Palm handheld or laptop computer with LRC software • Different regulation principles available according to supply air temperatures (see regulation diagrams)PART MATERIAL PART MATERIAL Casing Hot galvanized steel I/O unit Aluminium / plastic / electronics Spigots Hot galvanized steel and EPDM rubber Cables Halogen free InsulationMineral wool, s = 2 5 mm, MED Measurement wings Aluminium / polyurethane approved Cabin Unit HMR - 31081 HMR- Dual Duct Cabin Unit |
|