MN 1500 datasheet - Gazcon - #1

/ 1


catalogue search
MN 1500 datasheet - Gazcon
P. 01
Page:
MN 1500 datasheet - Gazcon


See other catalogues for Gazcon

Text version of the page

^ gazcon

Nitrogen generator MN1000

Features and benefits

• On-site nitrogen generator

• Based on Pressure Swing Adsorption (PSA) technology

• Fully automated, plug-and-play

• As standard calibrated to produce min. 988.0 (95.0%) Nm3/hour

Performance

Purity: (%)

95.00 98.00 99.50 99.90

Flow: (N2 Nm3/hour)

988.0 890.5 650.0 396.5

Air requirements: (Nm3/minute)

35.20 31.36 28.00 24.08

Unit performance +/- 5%

General specifications and requirements_ Included

• O2 monitor

Capacity at 95.0%:

Min. 988 Nm3/hour

Cost per Nm3 produced:

0.20 kW/ Nm3

Dew point: Inlet:

Outlet:

+3°C

-40°C

Outlet pressure:

5 bar

Inlet pressure requirement:

7.5 bar

Power supply: Generator:

Compressor:

240-110 V/ 50-60 Hz

400-440 V/ 50-60 Hz

Compressor requirements:

1 X 90 kW and 1 x 110 kW

Operating conditions:

Min 5°C - Max 45°C

Dry and ventilated room

Flow monitor

Flow regulator

Flow: 2 automatic

set-points

Alarms

Nm3 = +15°C & 1013 mbar

Scope of supply

Generator: Air supply: Boosting and filling:

Copyright © Gazcon A/S. All rights reserved.

Information subject to change without notice, v.2 2008-09-15

Gazcon A/S • Noglegardsvej 10 • DK-3540 Lynge • Tel. +45 44 99 69 00 • info@gazcon.com • www.gazcon.com


pageCatalog pdf ne En 2012-05-21-25