Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-F... Description Single and multipole magnetic circuit breakers with trip-free mechanism and toggle actuation. A choice of fast magnetic only or hydraulically delayed switching characteristics (S-type MO or HM CBE to EN 60934) ensures suitability for a wide range of applications. Industry standard dimensions and panel mounting. Options include auxiliary changeover contacts. Low temperature sensitivity at rated load. Approved to CBE standard EN 60934 (IEC 60934). Typical application Control equipment, communications systems, transportation, power supplies. Standard current ratings and typical internal resistance values Current rating (A) K1, M1, T1, M2, T2 0.02 2669 2457 0.05 452 376 0.1 100 94 0.25 15.5 14.7 0.5 3.9 3.2 0.75 1.65 1.56 1 0.95 0.90 2 0.26 0.20 2.5 0.15 0.15 3 0.10 0.10 5 0.042 0.040 6 0.029 0.028 8 < 0.02 < 0.02 10 < 0.02 < 0.02 12 < 0.02 < 0.02 15 < 0.02 < 0.02 16 < 0.02 < 0.02 20 < 0.02 < 0.02 25 < 0.02 < 0.02 30 < 0.02 < 0.02 40 ≤ 0.01 - 50 ≤ 0.01 - 8340-F... 1-pole 2-pole Technical data For further details please see chapter: Technical Information Voltage rating 3 AC 415 V; AC 240 V, 50/60 Hz; DC 80 V (higher DC ratings to special order) Current ratings 0.02...50 A single pole (40+50 A DC only) 0.02...30 A multipole Auxiliary circuit 6 A, AC 240 V; 3 A, DC 28 V 1 A, DC 65 V; 0.5 A, DC 80 V Typical life 3 AC 415 V, AC 240 V: 0.02...30 A 6,000 operations at 1 x IN, inductive 10,000 operations at 1 x IN, resistive DC 80 V: 0.02...25 A 6,000 operations at 1 x IN, inductive 0.02...30 A 10,000 operations at 1 x IN, resistive 40 + 50 A 6,000 operations at 1 x IN, resistive Ambient temperature -40...+85 °C (-40...+185 °F) Insulation co-ordination rated impulse pollution (IEC 60664 and 60664A) withstand voltage degree 2.5 kV 2 reinforced insulation in operating area Dielectric strength (IEC 60664 and 60664A) test voltage operating area AC 3,000 V pole to pole (2- and 3-pole) AC 1,500 V main to auxiliary circuit AC 3,000 V switching to trip circuit AC 1,500 V (version -X) Insulation resistance > 100 MΩ (DC 500 V) Interrupting capacity 6 x IN at AC; IEC 60934 - test sequence E 4 x IN at DC Interrupting capacity (UL 1077) AC: DC: IN 0.02...20 A 25...30 A 1-pole AC 250 V/3,500A AC 250 V/3,500A 2-pole AC 250 V/3,500A AC 250 V/5,000A 3-pole 3AC 250V/3,500A 3AC250V/5,000A 1-pole 0.02...50 A 2-pole 0.02...30 A DC 80 V/3,500 A DC 80 V/3500 A Degree of protection operating area IP40 (IEC 60529/DIN 40050) terminal area IP00 Vibration with toggle down: 10 g (57-2000Hz) ± 0.76 mm (10-57 Hz) at 0.9 x IN directions 1, 2, 3, 4, 5: 10 g (57-2000 Hz) at 1 x IN. Shock 100 g (11 ms) at 1 x IN, directions 1,2,3,4,5 Corrosion Humidity Mass Issue D www.e-t-a.de 100 g (11 ms) at 0.8 x IN, direction 6. 6 hours at 5 % salt mist, 9 to IEC 60068-2-11, test Ka 240 hours at 95 % RH to IEC 60068-2-78, test Cab approx. 65 g per pole 4 - 13 4

Open the catalog to page 1
8340-F - 2

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-F... Homologations Ordering information 4 Type No. 8340 magnetic circuit breaker with toggle actuator Mounting F flange mounting Configuration 4 with mounting nuts M3 9 snap-in frame Number of poles 1 single pole protected 2 two pole protected 3 three pole protected Panel hardware 0 without panel hardware Terminal design (main contact) K4 screw terminals with metric thread, M5 (IN = 20 A) P1 blade terminals Characteristic curve Characteristic curve K, short delay: K1 DC trip time at 2 x IN: 0.16-1.2 s Characteristic curve M, medium delay:...

Open the catalog to page 2
8340-F - 4

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-F... Terminal design / Dimensions Actuator configuration K4 screw terminals tightening torque max. 1.2 Nm Actuator design number of poles: 1 - 3 Configuration: F4 K4 screw terminals M5 1 1 4 3 Actuator long 2 OFF 0 9.7 .382 OFF 0 16 A 6 .236 9.4 .370 38.8 1.53 P1 blade terminals OFF 0 OFF OFF 0 OFF 0 OFF 0 OFF 0 OFF 0 16 A 16 A 16 A 16 A 0 16 A Actuator short OFF 0 OFF 0 16 A 16 A 1 4 3 2 9.6 .378 number of poles: 1 - 3 Configuration: F9 6 .236 38.8 1.53 blade terminals DIN 46244-A6.3-0.8 Auxiliary contacts version H (standard,...

Open the catalog to page 4
8340-F - 5

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-F... Typical time/current characteristics at 23 °C / +73.4 °F Curve K1 (short delay) for DC Curve M1 (medium delay) for DC 10000 10000 1000 Trip time in seconds 1000 Trip time in seconds 100 10 1 0.1 100 10 1 0.1 0.01 0.01 0.001 0.001 0 1 2 3 4 8 5 6 7 … times rated current 9 10 11 0 12 1 2 3 4 5 6 7 8 … times rated current 9 10 11 12 9 10 11 12 Curve K2 (short delay) for AC 50/60 Hz Curve M2 (medium delay) for AC 50/60 Hz 1000 1000 100 100 Trip time in seconds 10000 Trip time in seconds 10000 10 1 0.1 10 1 0.1 0.01 0.01 4 0.001 0.001 0 1...

Open the catalog to page 5

All E-T-A Elektrotechnische Apparate catalogs and brochures

  1. MPR10

    4 Pages

  2. SVS14

    6 Pages

  3. SVS15

    8 Pages

  4. SVS16

    6 Pages

  5. SVS18

    6 Pages

  6. SVS20

    8 Pages

  7. PP-M-PM024

    6 Pages

  8. PP-M-DC024

    6 Pages

  9. E-1048-8D...

    4 Pages

  10. 3131-A

    6 Pages

  11. ESR10

    4 Pages

  12. 1620

    2 Pages

  13. D_8340-G2

    5 Pages

  14. D_1120

    3 Pages

  15. D_1110

    2 Pages

  16. E-1048-8D

    3 Pages

  17. E-1048-8I

    5 Pages

  18. E-1048-8C.

    4 Pages

  19. 8340-G2

    5 Pages

  20. 1610-21

    3 Pages

  21. 1110

    2 Pages

Archived catalogs