D_8340-G2
5Pages

{{requestButtons}}

Catalog excerpts

D_8340-G2 - 1

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2... Description Single and two pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast magnetic only or hydraulically delayed switching characteristics (Stype MO or HM CBE to EN 60934) ensures suitability for a wide range of applications. Convenient threadneck panel or plug-in mounting, and with a white push button indicator band showing clearly the tripped/off position. Available with auxiliary contacts (1 x N/O, 1 x N/C) for status signalling and fitted with an unprotected shunt tap terminal as standard. Approved to CBE standard EN 60934 (IEC 60934). Typical application Control equipment, communications systems, power semiconductors. Standard current ratings and typical internal resistance values Current rating (A) 0.02 0.05 0.08 0.1 0.15 0.2 0.3 0.5 0.75 1 1.25 1.5 1.75 2 2.5 3 4 5 6 8 10 12 15 16 20 25 30 40 50 Internal resistance (Ω) per curve curves -F4 -E1/H1 583 2441 94 376 35.8 148 23 94 9.9 39 5 30.5 2.44 9.9 0.79 3.16 0.39 1.55 0.25 0.79 0.15 0.58 0.10 0.37 0.083 0.30 0.059 0.20 0.044 0.146 0.028 0.10 < 0.02 0.059 < 0.02 0.040 < 0.02 0.026 < 0.02 < 0.02 < 0.02 < 0.02 < 0.02 < 0.02 < 0.02 < 0.02 < 0.02 < 0.02 < 0.02 < 0.02 < 0.02* < 0.02 < 0.02* < 0.02 < 0.02 < 0.02 pole curves -H2/R2 2449 365 144 84 38 22.4 9.7 3.1 1.51 0.77 0.56 0.36 0.29 0.24 0.138 0.099 0.057 0.038 0.026 < 0.02 < 0.02 < 0.02 < 0.02 < 0.02 < 0.02 < 0.02 < 0.02 * 50 % ON duty / 60 min. Approvals Authority VDE (EN 60934) UL 1077, CSA CCC Issue D Voltage ratings 3 AC 415 V; AC 240 V; DC 80 V Current ratings 0.02...30 A DC 80 V DC 80 V 3 AC 250 V; AC 250 V 3 AC 415 V; AC 240 V DC 80 V 0.02...50 0.02...50 0.02...30 0.02...30 0.02...50 A A A A A 1-pole 1/2-pole 1,2-pole 1-pole 8340-G2... 2-pole Technical data For further details please see chapter: Technical Information Voltage rating 3 AC 415 V; AC 240 V, 50/60 Hz; DC 80 V (higher DC voltages to special order) Current ratings 0.02...50 A single pole (40+50 A DC only) 0.02...30 A double pole Auxiliary circuit 1 A, AC 240 V/DC 65 V 0.5 A, DC 80 V Typical life 3 AC 415 V, AC 240 V: 0.02...30 A 6,000 operations at 1 x IN, inductive 10,000 operations at 1 x IN, resistive DC 80 V: 0.02...25 A 6,000 operations at 1 x IN, inductive 0.02...30 A 10,000 operations at 1 x IN, resistive 40 + 50 A 5,000 operations at 1 x IN, resistive Ambient temperature -40...+85 °C (-40...+185 °F) Insulation co-ordination rated impulse pollution (IEC 60664 and 60664A) withstand voltage degree 2.5 kV 2 reinforced insulation in operating area Dielectric strength (IEC 60664 and 60664A) test voltage operating area AC 3,000 V pole to pole (2 + 3-pole) AC 1,500 V main to auxiliary circuit C 1,500 V A aux. circuit 11-12/23-24 AC 1,000 V switching to trip circuit (-X) AC 1,500 V Insulation resistance > 100 MΩ (DC 500 V) Interrupting capacity 6 x IN at AC; IEC 60934 - test sequence E 4 x IN at DC Interrupting capacity (UL 1077) AC: DC: IN 1-pole 2-pole 1-pole 2-pole 0.02...20 A AC 250 V/3,500A AC 250 V/3,500A 0.02...50 A 0.02...30 A 25...30 A AC 250 V/3,500A AC 250 V/5,000A DC 80 V/3,500 A DC 80 V/3500 A Degree of protection perating area IP40 o (IEC 60529/DIN 40050) terminal area IP00 Vibration with button down: 10 g (57-2000 Hz), ± 0.76 mm (10-57 Hz) at 0.9 x IN other mounting planes: 10 g (57-2000 Hz) at IN to IEC 60068-2-6, test Fc 10 frequency cycles/axis Shock 00 g (11 ms) at 1 x IN, directions 1,2,3,4,5 1 100 g (11 ms) at 0.8 x IN, direction 6 to IEC 60068-2-27, test Ea Corrosion 6 hours at 5 % salt mist, 9 to IEC 60068-2-11, test Ka Humidity 240 hours at 95 % RH to IEC 60068-2-78, test Cab Mass approx. 70 g per pole 1/2-pole www.e-t-a.de 4-7 4

Open the catalog to page 1
D_8340-G2 - 2

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2... ON OFF ø10.6 .417 ø8.4 .331 black white 57.5 2.26 1.5 .059 3 .118 12.5 .492 18.2 .717 6.5 .256 tightening torque max. 4 Nm M12x1 1.5 .059 1 11 23 2(i) 24 12 2(k) location pin for 3mm (.118 in.) hole dia. ø3+0,2 .118+.008 9.5±0.2 .374±.008 9.5 .374 0.8 .031 .492+.008 Cut-out dimensions: ø12.5+0,2 current rating in A SW14 .551 2.7 .106 Type No. 8340 Magnetic push/pull circuit breaker Mounting G threadneck panel mounting Threadneck design 2 M12x1 Number of poles (main current paths) 1 single pole, protected 2 two pole, protected Panel...

Open the catalog to page 2
D_8340-G2 - 4

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2... Typical time/current characteristics Short delay curves E1 for DC hydraulic-magnetic Curve F4 for DC, magnetic (undelayed) (IN >20 A, 50% ON period, 60 min.) at +23 °C / +73.4 °F 1000 1000 Trip time in seconds 10000 Trip time in second s 10000 100 10 1 0.1 100 10 1 0.1 0.01 0.01 0.001 0.001 0 1 2 3 4 6 8 5 7 … times rated current 9 10 11 0 12 Medium delay curves H1 for DC and H2 for AC 50/60 Hz, hydraulic-magnetic 2 3 4 6 8 5 7 … times rated current 9 10 11 12 9 10 11 12 Long delay curves R2 for AC 50/60 Hz, hydraulic-magnetic 1000...

Open the catalog to page 4
D_8340-G2 - 5

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2... Accessories Socket 18-P10-Si Polarized socket with adapter 18-P10-Si-20025 (for ratings >16 A please contact E-T-A) 5 .197 1.4 .055 33.3 1.31 25.8 1.02 6.5 .256 19 .748 80 3.15 top-hat rail EN 50022-35x7.5 adapter X 200 409 01 G profile EN 50035-G32 polarization recess SW14 .551 female connector thickness 0.4 mm .016 in. Splash seal, black, hex nut and O ring (IP54) X 200 802 01 (nickel plated hex nut M12x1, splash seal black) 4 SW 17 Actuator extension X 200 803 01 (black button) 10 .394 223 8.78 ø15 .591 M12x1 M4 copper rail...

Open the catalog to page 5

All E-T-A Elektrotechnische Apparate catalogs and brochures

  1. MPR10

    4 Pages

  2. SVS14

    6 Pages

  3. SVS15

    8 Pages

  4. SVS16

    6 Pages

  5. SVS18

    6 Pages

  6. SVS20

    8 Pages

  7. PP-M-PM024

    6 Pages

  8. PP-M-DC024

    6 Pages

  9. E-1048-8D...

    4 Pages

  10. 3131-A

    6 Pages

  11. ESR10

    4 Pages

  12. 1620

    2 Pages

  13. D_1120

    3 Pages

  14. D_1110

    2 Pages

  15. E-1048-8D

    3 Pages

  16. E-1048-8I

    5 Pages

  17. E-1048-8C.

    4 Pages

  18. 8340-F

    6 Pages

  19. 8340-G2

    5 Pages

  20. 1610-21

    3 Pages

  21. 1110

    2 Pages

Archived catalogs