D_1120
3Pages

{{requestButtons}}

Catalog excerpts

D_1120 - 1

Thermal Circuit Breaker 1120 Description Double pole combined circuit breaker and ON/OFF switch with rocker actuation. Specially suited to single-phase applications. Snap-in front panel mounting. Thermal positively trip free mechanism ensures reliable overcurrent protection and safe physical isolation of the load circuit. Attractively styled, with rocker illumination optional. The status of the switching contacts is shown by the position of the rocker actuator. For high volume requirements customer-specific designs can be offered for the front bezel and the rocker. It meets the requirements of the CBE standard EN 60934 (IEC 60934): S type, TO. Meets the requirements regarding fire resistance of EN 60335-1 : 2007-02 Safety of household and similar electrical appliances. 1120-.. without water splash protection Minimum ordering quantities apply! Typical applications with water splash protection 2 Technical data Electrical motors, household appliances, office equiment, garden and hobby tools, power supplies, charging rectifiers, cable extension reels, multiple socket outlets. Ordering information Type No. 1120 thermal circuit breaker Configuration F snap-in panel mounting Size of frame 1 panel thickness 1 - 2.5 mm (without water splash protection) 2 panel thickness 1 - 2 mm (with water splash protection) Number of poles 5 double pole, one pole thermally protected Design 0 standard 1 with water splash protection Terminal design P1 blade terminals 6.3x0.8 P2 blade terminals 6.3x0.8, 90° angled Characteristic curve T1 thermal Actuator style W rocker (latching switch) Actuator colour A black opaque B white opaque C red translucent D green translucent other colours upon request Actuator markings 00 „I“ and „O“ moulded in Illumination 0 without illumination B filament bulb Illumination voltage range 0 without illumination 3 AC 90 V - 140 V 4 AC 185 V - 275 V Current ratings 3...16 A Voltage rating AC 240 V; DC 32 V DC 50 V (only double pole) 3...16 A 10,000 operations at IN, inductive Current ratings Typical life Ambient temperature Insulation co-ordination (IEC 60664-1) Dielectric strength operating area terminal area pole/pole Insulation resistance Switching capacity Icn Switching capacity (UL 1077) Degree of protection (IEC 60529) Vibration Shock Corrosion Humidity Mass -20 °C...+60 °C 2.5 kV/2 reinforced insulation in operating area test voltage AC 3,000 V test voltage AC 1,500 V test voltage AC 1,500 V > 100 MΩ (DC 500 V) AC 240 V: 200 A, 1 and 2 pole DC 50 V: 200 A, 2 pole DC 32 V: 200 A, 1 and 2 pole AC 277 V: 3,500 A, 1 and 2 pole DC 50 V: 2,000 A, 2 pole DC 32 V: 2,000 A, 1 and 2 pole operating area IP40 with water splash protection IP66 terminal area IP00 8 g (57-500 Hz), ± 0.61 mm (10-57 Hz) test to IEC 60068-2-6, test Fc, 10 frequency cycles/axis 20 g (11 ms) test to IEC 60068-2-27, test Ea 48 hrs in 5% salt mist, test to IEC 60068-2-11,test Ka 96 hrs in 95% RH, test to IEC 60068-2-3, test Cab approx. 20 g Standard current ratings and typical internal resistance values operating voltage Current rating (A) Internal resistance (Ω) 0.09 10 ≤ 0.02 4 0.05 12 ≤ 0.02 0.04 14 ≤ 0.02 6 0.03 15 ≤ 0.02 8 ≤ 0.02 16 ≤ 0.02 filament/neon AC 115 V < 1.5 mA AC 230 V < 1.5 mA Issue D Internal resistance (Ω) 5 Illumination voltage/power consumption Current rating (A) 3 1120 - F 1 5 0 - P1 T1 - W B 00 0 0 - 10 A ordering example www.e-t-a.de 2 - 31

Open the catalog to page 1
D_1120 - 2

Thermal Circuit Breaker 1120 Dimensions single pole Dimensions double pole 1120-F1.0-P1.. 2.9 .114 9.5 OFF .374 OFF 40 1.57 36.4 1.43 1120-F...-P2 19 .748 15.8 10.2 .401 2 .079 33.3 1.31 90°+6° 9.5 .374 11.3 .445 2 2.5±0.2 .098±.008 9.5 .374 9.5 .374 28.5 1.12 2.5±0.2 .098±.008 9.5 28.5 .374 1.12 7.8 min. .307 min. Please provide opposite support when fitting the cable lug. 15.5 .610 blade terminals 6.3x0.8 to EN 60934 blade terminals 6.3x0.8 to EN 60934 with locating pin Applicable for nominal dimensions without direct tolerance indication: DIN ISO 286 ± IT13 Installation drawing...

Open the catalog to page 2
D_1120 - 3

©MMK Thermal Circuit Breaker 1120 Cut-out dimensions T1 - thermal characteristic curve Applicable for nominal dimensions without direct tolerance indication: Internal connection diagrams single pole connection double pole one pole thermally protected .. times rated current .. times rated current The time/current characteristic curve depends on the ambient temperature prevailing. In order to eliminate nuisance tripping, please multiply the circuit breaker current ratings by the derating factor shown below. This is a metric design and millimeter dimensions take precedence ( All dimensions...

Open the catalog to page 3

All E-T-A Elektrotechnische Apparate catalogs and brochures

  1. MPR10

    4 Pages

  2. SVS14

    6 Pages

  3. SVS15

    8 Pages

  4. SVS16

    6 Pages

  5. SVS18

    6 Pages

  6. SVS20

    8 Pages

  7. PP-M-PM024

    6 Pages

  8. PP-M-DC024

    6 Pages

  9. E-1048-8D...

    4 Pages

  10. 3131-A

    6 Pages

  11. ESR10

    4 Pages

  12. 1620

    2 Pages

  13. D_8340-G2

    5 Pages

  14. D_1110

    2 Pages

  15. E-1048-8D

    3 Pages

  16. E-1048-8I

    5 Pages

  17. E-1048-8C.

    4 Pages

  18. 8340-F

    6 Pages

  19. 8340-G2

    5 Pages

  20. 1610-21

    3 Pages

  21. 1110

    2 Pages

Archived catalogs