product Electrical - 16 Pages

  1. P. 1

  2. P. 2

  3. P. 3

  4. P. 4

  5. P. 5

  6. P. 6

  7. P. 7

  8. P. 8

  9. P. 9

  10. P. 10

Catalogue excerpts

www.daeyang.co.kr Marine Switchboards & Control Consoles Daeyang Electric Daeyang Electric HEAD OFFICE 503, Sinpyeong-dong, Saha-gu, Busan, Korea Tel. 82-51-200-5212, 5221, 5291, 5294, 5281 Fax. 82-51-200-5210 DAEYANG INSTRUMENT CO.,LTD. 502, Sinpyeong-dong, Saha-gu, Busan, Korea Tel. 82-51-200-5212, 5221, 5291, 5294, 5281 Fax. 82-51-200-5210 SEOUL OFFICE 4F Subon Bldg, 112-19, Samseong-dong Gangnam-gu, Seoul, Korea. Tel. 82-2-715-3492~3 Fax. 82-2-715~3495 DAEYANG ELECTRIC SUPPLY CO.,LTD. 317-2, Gupyeong-dong, Saha-gu, Busan, Korea Tel. 82-51-414-9937~9 Fax 82-51-414-9940 Printed in Korea September 2009 | Published by Daeyang Electric | Designed by Daeyang Design-Team

 Open the catalogue to page 1

2010 MARINE SWITCHBOARDS & CONTROL CONSOLE DAEYANG ELECTRIC MARINE SWITCHBOARDS & CONTROL CONSOLE Printed in Korea Septamber 2009 Published by Daeyang Electric Designed by Daeyang Design Team Head office 503, Sinpyeong-dong Saha-gu, Busan, Korea. Tel. 82-51-200-5212, 5221, 5291, 5294, 5281 Fax. 82-51-200-5210 Seoul office 4F Subon Bldg, 112-19, Samseong-dong Gangnam-gu, Seoul, Korea. Tel. 82-2-715-3492~3 Fax. 82-2-715~3495 Contents MARINE SWITCHBOARDS & CONTROL CONSOLE MAIN SWITCHBOARD 10 EMERGENCY SWITCHBOARD 13 GROUP STARTER 15 INDIVIDUAL STARTER 18 DISTRIBUTION BOARD 19 ENGINE CONTROL CONSOLE...

 Open the catalogue to page 2

Major Product Orginization Communication System team Offshore System team Sensor System team Lighting System team Design Team LED System team Environment System team Plant System team Lighting Indoor Light Outdoor Light Navigation Light & Signal Light Hazardous Area Light R&D CENTER Receptacle & Switch Reefer Container Receptacle LED General Affairs Team Accounting Team Procurement Team Communication-Navigation Administration Division Planning Team MIS Team Integreted Communication System (ICS) Refrigerated Container Monitoring System (RCMS) Sensor Power Cable Transmission System Temperature Sensor...

 Open the catalogue to page 3

Marine Switchboards & Control Consoles DAEYANG has much experience in design, manufacturing and testing of electrical and electronic equipment such as Main Switchboard, Control Consoles, Starters, and Power Distribution Panel for commercial marine and naval purposes. These products comply with the ruel requirements of major classification societies, Furthermore, the customers’ requirements can be completely satisfied with our special design and reliability system. DAEYANG will extend our state-of-the art technology to improve the quality and reliability www. da eya ng .c o. kr ww w.d aey an g....

 Open the catalogue to page 4

2004-09 DAEYANG Electric Co., Ltd. founded. Completed the development WICS (Wireless Interior Communication System) 1977-12 Since 1977 1977-05 2004-12 Designated as manufacturer of marine electric equipments by Ministry of Commerce Completed the development of Ni-Rh electronic reflector and Industry. 2005-05 1984-04 Expanded & moved Noksan factory for Blower & Ventilation Division Moved main office & factory to current location. (Shinpyong, Busan) 1985-09 2006-06 Selected as an “Excellent Exporting Company” by the Korea Development Bank. Certified as “INNO-BIZ” company by Small and Medium Business...

 Open the catalogue to page 5

SPECIFICATION Rated Voltage 600V AC (690 AC, option) Rated Current Withstand Current 8000A Max 120KA, rms, sym, 1 sec Rated Frequency Ambient Temperature 60Hz (50Hz, option) -10~45°C(50°C, option) relative Humidity 95% CONSTRUCTION Enclosure Protection Degree Front-Left hinged with door stopper Rear-Detachable type Handrail Front ( Rear- Option ) Insulation material A highly efficient insulation materials with sufficient mechanical strength against electromagnetic repulsive forces in case of short-circuits and against shock and/or vibration Painting color The MAIN SWITCHBOARD is newly designed...

 Open the catalogue to page 6

Synchronizing panel The synchronizing panel has the functions of power management system including auto synchronizing the generators. For automatic operation of generator, additional synchronizing and load sharing device can be provided on panel as option. Dimension of panel (unit : mm) NO. of generator 2 800(700) 3 900(800) 4 1000 5 Synchronizing panel Width Depth Height 1000 (700~1500) 2100 (1800~2300) Special Design 2 EMERGENCY SWITCHBOARD The EMERGENCY SWITCHBOARD is used for automatic start of emergency generator when power supply from main switchboard was failed. The panel consists of emergency...

 Open the catalogue to page 7

CONSTRUCTION Enclosure Formed sheet steel, totally enclosed, dead-front, floor mounting type Protection Degree IP 21, IP 22 (IP 23, option) Power Line Inlet Bottom or Upper part of the rear (upper part option) Door Front-Left hinged with door stopper Rear-Detachable type Handrail 3 Front (rear, option) GROUP STARTER TECHNICAL DESCRIPTION The emergency generator panel consists of ACB for emergency generator and a changeover switch with the type of a MCCB or an ATS (Automatic Transfer Switch). Bus-tie application The GROUP STARTER is a newly designed and manufactured for easy installation, space...

 Open the catalogue to page 8

SPECIFICATION Rated Voltage Dimension of unit and panel 600V AC (690 AC, option) Operating Voltage AC440/415/400/ 380/220/200V Rated Frequency 60Hz (50Hz, option) Control Voltage Ambient Temperature DC24V(if required) -10~45°C(50°C, option) UNIT (unit : mm) 95% Starting Method Motor capacity ( kw ) FVNR FVR 3.7 Relative Humidity 300(500) 350 5.5 300(500) 350 CONSTRUCTION Y- (P.S) R.S 7.5 300(500) 350 Enclosure Formed sheet steel, totally enclosed, floor mounting type 15 300(500) 350 550 Protection Degree • IP 21, IP 22 (IP 44, option) • Drip proof type 30 350(500) 650 650 900 37 450(600) 650 650...

 Open the catalogue to page 9

4 5 DISTRIBUTION BOARD INDIVIDUAL STARTER The INDIVIDUAL STARTER is smartly designed and requires less space for installation. The panel has two types, self-standing and wall-mounting and is suitable for easy installation and maintenance The DISTRIBUTION BOARD is suitable for distribution of power or lighting and requires less space for installation. The inside of pane has cover plate for safety of operators with pool-proof design which live parts are not exposed. SPECIFICATION Rated Voltage Rated Voltage 600V AC (690 AC, option) Ambient Temperature Operating Voltage AC480/415/400/380/220/200...

 Open the catalogue to page 10

All Daeyang Electric catalogues and brochures

  1. Instrument

    74 Pages

    En
  2. v.007 Fan

    20 Pages

    En
  3. v.007 LED

    44 Pages

    En
  4. product Light

    100 Pages

    En

Archived catalogues

  1. Berth Lights

    1 Pages

    En