Catalog excerpts

SERVICE MANUAL BINKS “TROPHY” SERIES PRESSURE AND SIPHON FEED HVLP, LVMP & CONVENTIONAL MANUAL SPRAY GUNS (2465-XXXX-XXXX) II 2 G X Binks Trophy Series Spray Gun is the premier spray gun for use in pressure and siphon feed spray applications and sets a new standard in durability, ergonomics, and atomization. The lightweight ergonomic design offers unsurpassed comfort and control. The latest advanced atomization technology has been incorporated for achieving consistent, fine finishes when spraying a wide range of industrial coating applications. Binks Trophy Series Spray Guns can be used with pumps, pressure pots, pressure cups, or siphon cups. Binks Trophy Series Spray Guns are offered in three different atomization technologies: HVLP, LVMP and Conventional. SPECIFICATIONS Maximum Air Pressure Maximum Fluid Pressure 1 40 psi / 9.6 bar (P-2) (with standard spring) Maximum Fluid Pressure The Trophy HVLP Series of Spray Guns can be used to operate at high transfer efficiencies in compliance with “California South Coast Air Quality Management District” regulations as a High Volume, Low Pressure spray gun. Anodized Aluminum Fluid Path Stainless Steel Fluid Inlet Size Wetted Parts Stainless Steel & PTFE IMPORTANT! DO NOT DESTROY It is the customer's responsibility to have all operators and service personnel read and understand this manual. Contact your local Binks representative for additional copies of this manual. READ ALL INSTRUCTIONS BEFORE OPERATING THIS BINKS PRODUCT.

 Open the catalog to page 1

EN In this part sheet, the words WARNING, CAUTION and NOTE are used to emphasize important safety information as follows: Hazards or unsafe practices which could result in severe personal injury, death or substantial property damage. Hazards or unsafe practices which could result in minor personal injury, product or property damage. Important installation, operation or maintenance information. Read the following warnings before using this equipment. READ THE MANUAL Before operating finishing equipment, read and understand all safety, operation and maintenance information provided in the operation...

 Open the catalog to page 2

EN TYPES OF INSTALLATION Air pressure for atomization is regulated at the extractor. The flow of the fluid is adjusted by the fluid valve control knob on gun, viscosity of paint and air pressure. PRESSURE CUP HOOKUP (Figure 1) For fine finishing with limited spraying. Air pressure for atomization is regulated at extractor; fluid pressure at cup regulator. Pressure cup is also available less regulator. PRESSURE TANK WITH 2 REGULATORS (Figure 2) Pressure Tank The pressure to the tank is regulated by the first regulator. The pressure for atomization is regulated by the second regulator. PRESSURE...

 Open the catalog to page 3

EN BINKS “TROPHY” SERIES SPRAY GUN The fluid inlet is not meant to be removed or replaced. Side port adjusting valve can be used as an optional air adjusting valve. NUMBERING SYSTEM FOR FULL SIZE BINKS “TROPHY” SERIES SPRAY GUNS 2465 – XXXX – XXXX CUP DESIGNATION 0 NO CUP S SIPHON CUP NEEDLE MATERIAL S STAINLESS (HARDENED) V VITREOUS (TUNGSTEN CARBIDE NEEDLE & NOZZLE) P PLASTIC TIP ATOMIZATION TECHNOLOGY CN CONVENTIONAL LV LVMP HV HVLP AIR CAP DESIGNATION 10 Series CONVENTIONAL 20 Series LVMP 30 Series HVLP See charts on page 6 for complete gun assemblies.

 Open the catalog to page 4

EN CHART 1: BINKS “TROPHY” SERIES SPRAY GUN PARTS LIST ITEM NO. PART NUMBER PART NUMBER AIR CAP RETAINING RING ASSEMBLY FLUID NOZZLE SIDE PORT VALVE ASSEMBLY KNOB – NEEDLE ADJUSTING NEEDLE PACKING KIT (STANDARD) NEEDLE PACKING KIT (VITREOUS) NEEDLE PACKING (STANDARD) NEEDLE PACKING (VITREOUS KIT OF 3) + SIDE PORT STEM • FRONT SEAL – AIR VALVE • FRONT AIR VALVE SEAL • REAR SEAL – AIR VALVE NEEDLE – STAINLESS STEEL (STD.) MARKING: I NEEDLE – FEATHERING NEEDLE – TUNGSTEN CARBIDE MARKING: II NEEDLE – PLASTIC TIP MARKING: III ❏ SPRING/PAD ASSEMBLY SPRING/PAD ASSEMBLY (STANDARD) (KIT OF 3) SPRING/PAD...

 Open the catalog to page 5

EN BINKS “TROPHY” SERIES SPRAY GUN PRESSURE FEED SPRAY GUN NEEDLE AND NOZZLE SELECTION GUIDE CHART 6: CONVENTIONAL GUN SET-UPS CHART 7: LVMP GUN SET-UPS TYPE OF FLUID TO BE SPRAYED COMPLETE GUN ASSEMBLY PART NUMBER 15-19 sec. Zahn 2 cup wash primers, dyes, stains, solvents, water, inks, sealers, laquers, lubricants, zinc chromates, acrylics TYPE OF FLUID TO BE SPRAYED synthetic enamels, varnishes, shellacs, fillers, primers, epoxies, urethanes, lubricants, wax emulsions, enamels wash primers, dyes, stains, solvents, water, inks, sealers, laquers, lubricants, zinc chromates, acrylics ADHESIVES...

 Open the catalog to page 6

EN BINKS “TROPHY” SERIES SPRAY GUN AIR CAP AND FLUID NOZZLE SELECTION CHARTS CHART 10: CONVENTIONAL AIR CAP AND FLUID NOZZLE SELECTION CHART Air Cap Spray Pattern Range Fluid Nozzle Typical Coatings Stains, Primers, Lacquers, Enamels, Acrylics, Reduced Latex, Mold Release Lacquers, Enamels, Top Coats, Low Viscosity Adhesives 45-11060 series, 2.0 mm – 2.6 mm or 45-11080 Tungsten Carbide Series (VT), 1.4 mm – 2.6 mm Zinc Rich, Adhesives, Glazes, Engobies, Ceramics, Porcelain Enamels CHART 11: LVMP – LOW VOLUME MEDIUM PRESSURE AIR CAP AND FLUID NOZZLE SELECTION CHART Air Cap Spray Pattern Range Fluid...

 Open the catalog to page 7

7. Turn fluid adjusting knob counter clockwise until first thread shows. 8. Test spray. If the finish is too dry, reduce airflow by reducing air inlet pressure. 9. finish is too wet, reduce fluid flow by turning fluid If adjusting knob (24) clockwise. If atomization is too coarse, increase inlet air pressure. If too fine, reduce inlet pressure. 10. he pattern size can be reduced by turning sideport T control (9) clockwise. 11. old gun perpendicular to surface being sprayed. Arcing H or tilting may result in uneven coating. 12. he recommended spray distance is 8 inches. T 13. pray edges first....

 Open the catalog to page 8

REMOVAL AND INSTALLATION PROCEDURES NEEDLE AND VALVE DISASSEMBLY AND ASSEMBLY FIG.1

 Open the catalog to page 9

EN MAINTENANCE – FLUID NOZZLE AND BAFFLE REMOVAL AND INSTALLATION FIG.1 AIR CAP INDEX PIN (54-6184) INSTALLATION (OPTIONAL – 90° INCREMENTS INDEXING FEATURE) FIG.1

 Open the catalog to page 10

All Binks catalogs and brochures

  1. MX1212 Pump System

    24 Pages

    En
  2. MX412 Pump System

    28 Pages

    En
  3. Model 7 Spray Gun

    12 Pages

    En
  4. Trophy Siphon

    80 Pages

    En
  5. Trophy Gravity

    80 Pages

    En
  6. GEMS 240-5100

    16 Pages

    En
  7. MAG AA Automatic

    8 Pages

    En

Archived catalogs

  1. Trophy series

    10 Pages

    En