BESI Tank Level Gauging - BESI Marine Systems - #1

/ 2


catalogue search
BESI Tank Level Gauging - BESI Marine Systems
P. 01
BESI Tank Level Gauging - BESI Marine Systems
P. 02
Pages:
BESI Tank Level Gauging - BESI Marine Systems


See other catalogues for BESI Marine Systems
You may also be interested in

Anti-heeling system, Level sensor, Sensor for ships, Sensor


Text version of the page
H G F E D C B A 11 10 9 8 7 6 12 11 10 9 8 7 6 02010DINISO 1 F1 Unterteil 1 Kolben 1 Zylinder 1 Endschalterhalterung 1 Verdrehsicherung 1 Verdrehsicherung 1 Hebel 1 BREMEN BERG + SIEBERT BESI ARMATUREN BREMEN pressure connection for emergency hand pump, opening pressure C1(D1(NA) = Druckanschluß für Nothandpumpe, Datum Zust Datum Änderung Nam. Norm Gepr. Bear. 24.6.03 Allgemeintoleranz ISO 2768-m d:\hst2p\100100\From factory all connections are locked with balls. Incl. all quick couplings and progressiv ring ttings OD 8 mm. Werksseitig sind alle Verschraubungen mit einer Kugel dichtgesetzt. Incl. aller Schnellkupplungen und Schneidringverschraubungen Rohr-ø 8 mm. Drehmoment bei 100 bar önen opening schließen closing 11780 Nm torque at 100 bar 11780 Nm C M24x80 A C B D D C1 D1 180 58 C M24x80 D A C B D D C1 D1 C 210 180 180 58 TLG Tank Level Gauging and Draft Measurement Phone +49 (0) 421/57 64 3-0 Fax +49 (0) 421/58 36 21 e-mail info@besi.de web www.besi.de BESI Marine Systems GmbH & Co. KG Knechtsand 4 • 28259 Bremen Germany BESI Marine Systems GmbH & Co. KG F L OW MA N A G EME N T BMarine SyEstems GmSbH & CoI. KG WWW. B E S I . D E General description The process pressure / hydrostatic pressure sensors are based on the principle of a transducer with a pre-set pressure range and adjustable output. The sensors can be installed “dry” outside the tank, or “submerged” in medium inside the tank. In both cases, the sensor should be installed approx. 10cm above the lowest bottom area of the tank. Applications • Ballast water tanks, fresh water tanks, grey water tanks. black water tanks, sludge tanks. • HFO Storage tanks, HFO Settling tanks, HFO Service tanks. • MDO tanks, lube-oil tanks, cooling water tanks. • Draft S Y S T EM I N F O RMAT I O N Pressure Sensors SENSOR FEATURES FOR PRESSURE TRANSDUCERS: A Principle: process pressure/hydrostatic pressure Exactitude: better <0,25 % Overpressure: at least 25 bar overpressure-safe Temperatures: body –10 ..+ 100 °C Materials: membrane is sapphire-ceramic, body 1.4404, sealing FFKM double sealing Protection: D =IP67 / S= IP 68 , on request ATEX II 2G EEx ia IIC T6 Power supply: 24 V DC, 11 ... 32V, output: analogue 4 – 20 mA Electrical connection: via vented junction box with PG 13,5 cable glands Approvals: GL, LRS, ABS, CCS, RINA, DNV Visualization of tank levels The visualization of tank and draught levels is realized on an existing control panel of the RCV remote controlled valve system, ballast system, ship automation / alarm system, or as a standalone solution on a colour touch panel display. The panels are available from 10.4” up to 19”. The TLG system can be used as a stand-alone application or as an integrated solution in the RCV system. The interface to the Alarm & Monitoring System (AMS) and / or ship management system is via RS485 or Ethernet. Both interface types are most common and, furthermore, are highly reliable and flexible. Examples of possible sensor installations S Y S T EM I N F O RMAT I O N Tank Level Gauging and Draft Measurement for continuous level management R E F E R E N C E S Partnership in Flow Management We associate with nearly all major shipyards worldwide. Until this moment, more than 4000 ships and offshore facilities have been equipped with BESI systems. To get a complete reference list, please get in contact with us.

pageCatalog pdf ne En 2012-05-21-24