PN
PA
PN = Druckanschluß für Nothandpumpe
PA = Druckanschluß für Önungszylinder
pressure connection for opening cylinder
pressure connection for emergency hand pump
Änderungen vorbehalten!
modication without notice
Hydr. Antrieb
PN Datum
Zust Änderung Norm
Gepr.
Bear.
Werksto, Halbzeug
Maßstab
Name
(Gewicht)
25.4.08 ES
Allgemeintoleranz
ISO 2768-m
Önungszylinder
opening cylinder
Schnitt A - A
34
23
2
24
4
1
23
6 50 36 52 53
K
3 4 5 6 7 8 9 10 11 12 From factory all connections are locked with ball's.
Incl. all quick couplings and progressiv ring ttings OD 8 mm.
BESI Marine Systems
BREMEN / GERMANY
PA
A
A
= Vorfertigung 0.500
Art.Nr.1011 00 4415
= Vormontage 0.53 (KN3)
Art.Nr.1011 00 4424
= Endmontage 0.53 (KN4)
Art.Nr.1011 00 4425
38
48 40,42 46 44 41 47 45
AHS
BESI Anti-Heeling System
Phone +49 (0) 421/57 64 3-0
Fax +49 (0) 421/58 36 21
e-mail info@besi.de
web www.besi.de
BESI Marine Systems
GmbH & Co. KG
Knechtsand 4 • 28259 Bremen
Germany BESI Marine Systems GmbH & Co. KG
F L OW MA N A G EME N T BMarine SyEstems GmSbH & CoI. KG
WWW. B E S I . D E
S Y S T EM I N F O RMAT I O N
AHS Configuration
Inclinometer
This sensor provides the calibrating input signal
for the anti-heeling control system. BESI
recommends this inclinometer to be installed
in the control cabinet which has to be mounted
in transversal direction of the ship.
If this is not possible, the inclinometer should
be arranged transversally and rigid to the
ship’s structure, in a small box near the control
cabinet.
Operator Panel
This panel is designed
to monitor
and operate the
AHS from remote
position, for example,
from the
wheelhouse. The
panel is prepared for flush mounting into an
existing control console.
Stability Test
This feature is optional and comes with a printer
for documenting the test reports. The testing
procedure is based on the regulations of IMO.
RES. A 749 (18) Chapter 7.3.1.
The BESI AHS is designed according to the
Germanischer Lloyd (GL) rules and is also typeapproved
by GL.
STARTUP
a
b
c d
GM1
a
b GM2
c d
a
b
c
GM3
d
a
b
c d
GM4
END
to PS
to STB
1°
1°
2°
2°
R E F E R E N C E S
Partnership in
Flow Management
We associate with nearly all major shipyards
worldwide. Until this moment, more than 4000
ships and offshore facilities have been equipped
with BESI systems. To get a complete reference