116-P-BS320/CE - Rev. F, 2005-05-31 Protecting life, environment and property... Features • Self-Verify function for automatic testing of detectors • Automatic addressing of detectors • Accommodates up to a maximum of 12 modules, of which maximum six can be Loop Driver Modules • User-friendly display and operator controls • Backlit operational buttons. Text display suitable for full darkness operation • Surface or flush mounting, or rack mounting in standard 19’’ cabinets • Designed to meet EN-54 and LPCB requirements, and conforms to CE standards • Complies with environmental conditions of IEC-721-3-3 class 3k5 Application/Description BS-310/320 is a complete fire alarm control panel with full operation capabilities. The panel serves as an operating panel for one or several defined operation zones. All alarm handling and system features can be controlled and monitored from the panel. The panel can accommodate up to a maximum of 12 modules. The system offers a Loop Driver Module for detector loops and several types of I/O modules for monitored outputs, open collector outputs, galvanic isolated inputs and monitored inputs. There can be a maximum of six Loop Driver Modules in each panel. All modules are easily plugged onto each other on a standard mounting rail inside the unit. The panel is menu operated on a 16-line display, with 40 characters per line. A built-in printer is available as an option. With a LON Interface the Fire-Alarm Control Panel can communicate with other system units on the local operating network, AutroLON. This interface is standard in BS-320, and not included in BS-310. The panel has a 230VAC/3A power module for battery charging, and a built-in emergency battery. Indicators • 16 x 40-character alphanumeric display • Fire/Alarm, More Events, Fault, Function Disabled, Function Delayed, Fire Brigade Signaled, Power, Testing, Fire Brigade Disabled, Fire Brigade Fault, System Fault, Alarms Disabled, Alarms Fault • Internal buzzer Operator Controls • More Events, Mute Panel, Silence Alarms, Reset • Keyboard with alphanumeric characters and scroll function • Separate buttons for menu operation • Backlit buttons and text Optional I/O Modules • Loop Driver Module (BSD-310/311). For connection of detector loops. One detector loop can be connected to each module. A maximum of 127 loop units (detectors, manual callpoints, I/O-units and/or electronic sounders) can be connected to each detector loop • Output Module (BSB-310), with four monitored outputs. For connection to fire-alarm devices (FAD), such as sounders etc., and fire-protection equipment (FPE) such as fire doors, ventilation controllers or fire extinguishers. Also suitable for connection to fire-alarm routing equipment (FARE), such as fire brigade equipment, and for connection to fault outputs • Output Module (BSJ-310), with eight open collector, nonmonitored outputs. For connection of external LED-indication panel • Input Module (BSE-310) with four monitored inputs • Input Module (BSE-320), with eight non-monitored inputs (galvanic isolated) Capacity • There can be a maximum of 32 panels in a LON ring (EN-54). A demand for more than 32 panels requires several LON rings • Each unit can be equipped with a maximum of 12 of the above modules, of which maximum six can be Loop Driver Modules (cabinet without internal batteries) • A maximum of 512 detectors and manual call-points can be connected to each Fire-Alarm Control Panel (EN-54) AutroSafe Fire-Alarm Control Panel – BS-310/320

pageCatalog pdf ne En 2012-05-21-23