JUMP JACKET MK4 THE JUMP JACKET Mk4 INTRODUCTION  The Jump Jacket Mk.4 has been designed to be used in the commercial diving industry,  specifically for surface air and mixed gas diving, to allow the diver total control of his buoyancy.  The emphasis has been heavily placed on safety and efficiency, allowing the diver greater  flexibility under water without drawing on emergency energy levels. Expanding on the safety  features of the MK.3 Jacket, the general concept is to give the diver more control of his buoyancy  and expand his options in an emergency situation. GENERAL DESCRIPTION  The Mk.4 Jacket has been designed to be used in conjunction with a KMB.17 b/c diving helmet. ...

 Open the catalogue to page 2

JUMP JACKET MK4 INSTRUCTIONS FOR OPERATION AND USE 1. 1.1 DONNING  The Jump Jacket is designed to be worn as a single unit without the need for any  other harnesses. With the jacket and bailout supported, the diver steps into the  continuous loop leg straps and then passes his arms through the waistcoat  jacket. Ensure that the primary lifting  D ring is accessible between the diver’s shoulder blades. The waist, chest and  leg straps can now be adjusted for a comfortable fit. 1.2 GAS SUPPLY  The Jump Jacket Mk4. has four independent gas supplies available: 1.2.1 1.2.2 SECONDARY GAS SUPPLY (PNEUMO...

 Open the catalogue to page 4

JUMP JACKET MK4 INSTRUCTIONS FOR OPERATION AND USE (cont.) 1.2 GAS SUPPLY (continued) 1.2.4 DIVER TO DIVER (UMBILICAL CROSS CONNECT)  The  umbilical  cross  connect  is  used  in  an  emergency  situation  and  allows two divers to buddy breathe from one umbilical gas supply. This  is  achieved  by  disconnecting  the  quick  connect  fitting  from  the  jacket  supply  valve  of  one  diver,  disconnect  the  quick  connect  fitting  on  the  second  diver’s  helmet  and  connecting  in  the  first  diver’s  jacket  supply  hose to the second diver’s helmet. (See Fig. 1)  The two divers are now able to breathe from the one umbilical. ...

 Open the catalogue to page 5

JUMP JACKET MK4 INSTRUCTIONS FOR OPERATION AND USE (cont.) 2. OPERATION 2.1 BUOYANCY CONTROL  The Jump Jacket offers a maximum buoyancy of 22.72kg. Control of jacket  buoyancy is achieved by a combination of the diver injecting gas from his chosen  gas supply and dumping gas via either dump valve. Choice of gas supply would  be dependent on the diving set­up and the situation that the diver finds himself in.  As gas is injected, the diver should grasp one of the two dump cord toggles,  situated on either shoulder of the jacket. By operating the gas supply and dump  valves in sequence, the diver will be able to achieve his required...

 Open the catalogue to page 6

JUMP JACKET MK4 INSTRUCTIONS FOR OPERATION AND USE (cont.)  A second lift point is provided by means of two harness extensions, positioned  inside the front wings of the jacket and can be pulled together to form a front  lifting point. (See Fig. 3)  Fig.2  Fig.3  The harness has two umbilical D ring positions and diver rigging  D rings on the leg straps.  For safety reasons the leg straps are permanently fitted through the  roller/adjuster buckles, forming permanent loops that the diver will have to step  into when dressing.  This harness is only to be used in conjunction with the Jump Jacket and is not ...

 Open the catalogue to page 7

JUMP JACKET MK4 INSTRUCTIONS FOR OPERATION AND USE (cont.) 3. DIVER RECOVERY  The Mk4 Jump Jacket has been designed to assist in the recovery of an injured,  unconscious, or trapped diver. 3.1 DIVER RECOVERY (UNCONSCIOUS DIVER)  The use of the Mk.4 Jump Jacket to assist in an emergency diver recovery as  been greatly advanced. The ability to float an unconscious diver back to a diving  bell or recovery basket has proven to be a major safety feature. The  bellman/standby diver is able to use the unconscious diver's Jump Jacket to lift  him above the seabed or obstruction and then concentrate his efforts on the ...

 Open the catalogue to page 8

JUMP JACKET MK4 INSTRUCTIONS FOR OPERATION AND USE (cont.) a.  b.  Disconnect the quick  connect fitting from the  Recovery Diver’s  inflation valve to his  jacket (See Right) c.  Pull out the extended  inflation hose from the  Recovery Diver’s jacket pouch and connect the jacket inflation hose into  the Trapped Diver's helmet side­block quick­connect fitting. The Trapped  Diver is now breathing from the Recovery Diver’s main umbilical gas  supply. d.  The Trapped Diver's main umbilical can now be cut to allow  his recovery back to the bell. N.B.  4. The Recovery Diver  would disconnect the  quick connect fitting ...

 Open the catalogue to page 9

JUMP JACKET MK4 INSTRUCTIONS FOR OPERATION AND USE (cont.)  Time must be allowed during a course of operational dives for those  divers who are new to the Jump Jacket to explore the versatility of the  jacket at their own pace. Each diver will experience a different learning  curve before building up enough confidence to use the jacket to its full  potential. 4.2 TRAINING (TECHNICIAN)  Equipment Technicians should be fully trained on all aspects of the  Jump Jacket and be able to implement a full service and maintenance  program.  It is recommended that the following maintenance program be employed ...

 Open the catalogue to page 10

JUMP JACKET MK4 MAINTENANCE AND COMPONENTS 5. GENERAL  A  regular  maintenance  program  should  be  followed  to  ensure  reliability  of  the  jacket  through  its  working  life.  It  is  recommended  that  the  jacket  be  taken  out  of  service  and  visually  inspected  for  damage  or  wear  approximately  every  10­  15  dives  or  in  conjunction  with  the  diving  helmet  maintenance  program.  The  jacket can be hand washed in a mild soap water solution.  A  porosity  test  should  be  carried  out  to  confirm  integrity  of  the  inner  bladder  and  valves.  All  valves  should ...