Analog signal converters, Serial data converters Product group picture 4/1 ABB | Catalog Electronic Products and Relays 2013/2014 | 2CDC 110 004 C0209

 Open the catalogue to page 1

Analog signal converters, Serial data converters Analog signal converters, serial data converters Analog signal converters - CC-E range 4/5 Ordering details - Standard signal converters 4/8 Ordering details - RTD converters 4/9 Ordering details - Thermocouple converters 4/10 Ordering details - Measuring converters 4/11 DIP switch settings and dimensional drawings 4/12 Analog signal converters - CC-U range 4/17 Ordering details - Accessories 4/22 Technical diagr., Connection diagr., Dimensional drawings 4/32 Serial data converters 4/33 Connection diagrams and jumper settings 4/38 2CDC 110 004 C0209...

 Open the catalogue to page 2

Analog signal converters, Serial data converters Overview Applications for analog signal processing and correct solution using CC-E and CC-U converters Nearly every process includes a control system that receives data by means of analog signals and then evaluates the data and sets the respective parameters correspondingly. Controller e.g. AC500 1. Analog signal converter (e.g. CC-E or CC-U) 2. Analog signal converter (e.g. CC-E or CC-U) When transmitting analog signals numerous problems may arise which can disturb or even block an ideal behavior of the process. 100 m Below we have listed some...

 Open the catalogue to page 3

Analog signal converters, Serial data converters Overview In the field of industrial data transmission, various processes of data transmission and interfaces are used today. Already existing systems need to be updated or connected to new devices for continuity of process. When new communication functions are not build-in, ABB propose a range of converters to be able to use from the standard RS232 or RS485, to the Ethernet open products or the Optical Fiber. Ethernet communication is now one of the main features need in open communication, ABB propose the e-ILPH to connect the serial devices to...

 Open the catalogue to page 4

Analog signal converters - CC-E range Product group picture 4/5 ABB | Catalog Electronic Products and Relays 2013/2014 | 2CDC 110 004 C0209

 Open the catalogue to page 5

Analog signal converters - CC-E range Analog signal converters - CC-E range Product group picture 4/5 Ordering details - Standard signal converters 4/8 Ordering details - RTD converters 4/9 Ordering details - Thermocouple converters 4/10 Ordering details - Measuring converters 4/11 DIP switch settings and dimensional drawings 4/12 2CDC 110 004 C0209 | Catalog Electronic Products and Relays 2013/2014 | ABB 4/6

 Open the catalogue to page 6

Analog signal converters - CC-E range Benefits and advantages 1 Terminal explanation Adjustment of gain 4 Adjustment of offset 4 Indication of operational states U - control supply voltage applied 2 3 CC-E range Universally configurable devices and single-function devices Adjustment and operating elements on the front side Safe operation by electrical 3-way isolation Unambiguous and clear connecting terminal markings Conversion, measurement and separation of Standard signals (0-5 V, 0-10 V, 0-20 mA, 4-20 mA) Temperature signals of RTD sensors (PT 100) Thermocouple signals (types J and K) Current...

 Open the catalogue to page 7

Analog signal converters - CC-E range Ordering details - Standard signal converters Ordering details - Standard signal converters Input signal Output signal Supply voltage range Order code loop powered B 1604 Class I, Div.2 (universal device) 2) CC-E-I/I-1 has 1 channel, CC-E-I/I-1 has 2 channels with relay output 2CDC 110 004 C0209 | Catalog Electronic Products and Relays 2013/2014 | ABB

 Open the catalogue to page 8

Analog signal converters - CC-E range Ordering details - RTD converters Ordering details - RTD converters Supply voltage range Input signal Output signal Order code B 1604 Class I, Div.2 (universal device) 2) CC-E-I/I-1 has 1 channcel, CC-E-I/I-1 has 2 channels with relay output 4/9 ABB | Catalog Electronic Products and Relays 2013/2014 | 2CDC 110 004 C0209

 Open the catalogue to page 9

Analog signal converters - CC-E range Ordering details - Thermocouple converters Ordering details - Thermocouple Converters Input signal Output signal Supply voltage range Order code with relay output 2CDC 110 004 C0209 | Catalog Electronic Products and Relays 2013/2014 | ABB

 Open the catalogue to page 10

Analog signal converters - CC-E range Ordering details - Measuring converters Ordering details - Measuring Converters Output signal Input signal Supply voltage range Order code with relay output 4/11 ABB | Catalog Electronic Products and Relays 2013/2014 | 2CDC 110 004 C0209

 Open the catalogue to page 11

Analog signal converters - CC-E range DIP switch settings, Dimensional drawings CC-E/STD, CC-E x/x (universal devices) Select input range by terminals Connected lines Used terminals Terminal marking Connected lines Used terminals Terminal marking Dimensional drawings 2CDC 110 004 C0209 | Catalog Electronic Products and Relays 2013/2014 | ABB 4/12

 Open the catalogue to page 12

Analog signal converters - CC-E range Wiring instructions CC-E/STD, CC-E x/x (universal devices) 4/13 ABB | Catalog Electronic Products and Relays 2013/2014 | 2CDC 110 004 C0209

 Open the catalogue to page 13

Analog signal converters - CC-E range Technical data Type Input circuits - Analog inputs Input signal Temperature sensors Rated input range Limitation of input signals Influence of line resistance Gain adjustment range Offset adjustment range Input impedance Common-mode rejection Output circuits - Analog outputs Output signal Output burden Residual ripple Response time Transmission frequency 80 Hz 2 Hz (up to -3 dB) High fail safe: Output voltage > 115 % of measuring 2) range Low fail safe: Output voltage < -0.6 V, output current = 0 mA Reaction to input circuit interruption Supply circuits Supply...

 Open the catalogue to page 14

Analog signal converters - CC-E range Technical data Type Input circuits - Analog inputs Input current IIN Input voltage drop Ui Output circuits Output current IOUT Output voltage UOUT Residual ripple Response time (0-100 %) Accuracy Load influence (0-500 ) Mounting position Ambient temperature range Temperature coefficient Electrical connection rigid 0.2-4 mm2 (24-12 AWG) Wire size fine-strand with(out) wire end ferrule 0.2-2.5 mm2 (24-14 AWG) Stripping length Tightening torque Standards Product standard Interference immunity electrostatic discharge (ESD) electromagnetic field (HF radiation resistance) fast...