2013 Product selector - 06 Relays: control relays, timers & controls complete section - 300 Pages

  1. P. 1

  2. P. 2

  3. P. 3

  4. P. 4

  5. P. 5

  6. P. 6

  7. P. 7

  8. P. 8

  9. P. 9

  10. P. 10

  11. P. 20

  12. P. 30

  13. P. 40

  14. P. 50

  15. P. 60

  16. P. 70

  17. P. 80

  18. P. 90

  19. P. 100

  20. P. 200

  21. P. 300

Catalogue excerpts

Control, timing & monitoring relays Index 6 - Control, timing & monitoring relays Continued next page Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage

 Open the catalogue to page 1

Relays Index Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage

 Open the catalogue to page 2

tro Industrial control relays l re lay Pilot duty rated for control circuits s Positively guided, AC & DC controlled Control relays Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage K / KC control & interface relays 4 & 8 pole control relays Pilot duty rated up to 10 A For AC & DC control circuit switching Electronic AC/DC coil input voltages NFZ with low power consumption coils Direct PLC control ≥ 24VDC, 500mA (NFZ) Mechanically linked contacts for safety Wide variety of accessories 4 pole miniature control relays Compact solutions up to 10 A Quick-connect & PCB...

 Open the catalogue to page 3

Control relays Mini control relays - 4 pole I EC AC-15 Rated operational current 400 V UL/CSA Pilot duty DC Control supply |=| Type AC / DC Control supply Type I EC AC-15 Rated operational current 400 V A UL/CSA Pilot duty AC Control supply |^\^| Type DC Control supply |===| Type AC / DC Control supply Type Low Voltage Products & Systems

 Open the catalogue to page 4

General information Panorama Control relays – 4 pole Control relays – 8 pole Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage

 Open the catalogue to page 5

General information Technical terms and definitions Refers to the height of the site where the equipment is located, expressed in meters above the sea level. Ambient temperature Rated control circuit voltage Uc Control voltage value for which the control circuit of the unit is sized. Rated insulation voltage Ui Temperature of the air surrounding the unit. Voltage value which designates the unit and to which dielectric tests, clearance and creepage distances are referred. Rated impulse withstand voltage Uimp All the conducting parts of a contactor, intended to be included in a circuit different...

 Open the catalogue to page 6

General information IEC Standards, utilization categories Standards • IEC standards 158-1: “Contactors” and series IEC 292 : “Motor-starters” have been revised and replaced by the new IEC 947-4-1 (1990-05): “Contactors and Motor-starters” referring to IEC 947-1 (1988): “General rules” The new standards will constitute the basis of the future European and National standards, not yet revised. Therefore the ratings indicated in this catalog are established according to the former and the future standards. • Main changes and additions in the new standards are: • Revision and extension of the utilization...

 Open the catalogue to page 7

General information Pilot duty ratings and overload trip classes Pilot duty ratings for AC control circuit contacts Contact rating designation Continuous thermal, test current (A) Mechanical switching ratings and test values as published in Table 1-4-1 of NEMA ICS 5-2000 (R2005, R2010) Pilot duty ratings for DC control circuit contacts Contact rating designation Continuous thermal, test current (A) Make / Break Make / Break Make / Break Make / Break Mechanical switching ratings and test values as published in Table 1-4-1 of NEMA ICS 5-2000 (R2005, R2010) Pilot duty rating explanation A - 600 Max....

 Open the catalogue to page 8

General information NF/NFZ control relays 4 & 8 pole Control circuit types Control relay types NF / NFZ control relays are provided in either four or eight auxiliary pole configurations with a variety of accessories including additional auxiliary contacts and electronic timers. NF / NFZ control relays are pilot duty rated and primarily used for switching both AC and DC control circuits. NF / NFZ coils are designed to utilize both AC (50/60 Hz) and DC control circuit inputs ranging from 12…500V. Surge suppression is included. NFZ types offer low power consumption coils. 6 Quick DIN-rail mount &...

 Open the catalogue to page 9

NF, 4 & 8 pole For pilot duty applications up to 10 A Electronic AC/DC operated coils Description –– NF control relays include an electronic coil interface accepting a wide control voltage Uc min. ... Uc max. Only four coils cover control voltages between 24...500 V 50/60 Hz or 20...500 V DC –– NF control relays can manage large control voltage variations. One coil (i.e. 100...250 V 50/60 Hz - DC) can be used for different control voltages used worldwide without any coil change –– NF control relays have built-in surge protection and do not require additional surge suppressors –– The control relays...

 Open the catalogue to page 10

NFZ, 4 & 8 pole For pilot duty applications up to 10 A Low power consumption, electronic AC/DC operated coils Description –– NFZ control relays include an electronic coil interface accepting a wide control voltage Uc min. ... Uc max. and managing large control voltage variations. NFZ control relays cover control voltages between 24...250 V 50/60 Hz or 12...250 V DC –– NFZ control relays allow direct control by PLC-output ≥ 24 V DC 500 mA and obtain a reduced holding coil consumption. NFZ control relays withstand short dips and voltage interruptions (SEMI F47-0706 compliance) –– NFZ control relays...

 Open the catalogue to page 11

NS/NSL 4 & 8 pole For pilot duty applications up to 10 A AC or DC operated coils, bulk packaged for high volume Description NS/NSL contactor relays are used for switching auxiliary and control circuits. These contactor relays are designed with: • 4 poles or 8 poles. Contactor relays have mechanically linked auxiliary contact elements (side-marked symbol) • Suitable for direct PLC control (DC 3W) • add-on auxiliary contact blocks for front mounting and a comprehensive range of accessories. Ordering details Number of contacts 1st stack Rated control circuit voltage Uc Rated control circuit voltage...

 Open the catalogue to page 12

NS/NSL 4 & 8 pole, spring terminated For pilot duty applications up to 10 A AC or DC operated coils, bulk packaged for high volume Description NS/NSL contactor relays are used for switching auxiliary and control circuits. These contactor relays are designed with: • 4 poles or 8 poles. Contactor relays have mechanically linked auxiliary contact elements (side-marked symbol) • Suitable for direct PLC control (DC 3W) • add-on auxiliary contact blocks for front mounting and a comprehensive range of accessories. Ordering details Number of contacts 1st stack 2nd stack 4 pole Standard bulk pack quantities...